![Taramps HOMEE TPS 6000 Instruction Manual Download Page 12](http://html2.mh-extra.com/html/taramps-0/homee-tps-6000/homee-tps-6000_instruction-manual_4991910012.webp)
AMBIENTE 4
TOTAL: 100RMS MONO
To connect to ceiling speakers, use cables with a minimum gauge of 1.5mm² for up to 40 meters.
For longer distances, see table on page 02 ‘‘Important recommendations’’. It is necessary to make
connections in parallel and series as shown in the example, to match impedance.
Example 1:
System 2.1 with four bookshelf speakers
+ 1 passive bass speaker. All 4 ohms.
CH3/CH4: X-OVER in LPF, ROUTE in L+R
CH1/CH2: X-OVER in HPF, ROUTE in L/R
Example 2:
Two full range TOWER boxes 200W each.
Both 4 ohms
CH1/CH2: X-OVER in OFF, ROUTE in L
CH3/CH4: X-OVER in OFF, ROUTE in R
Example 3:
Eight 4 ohm ceiling speakers working in
stereo for two commercial rooms:
CH1/CH2: X-OVER in HPF, ROUTE in L/R
CH3/CH4: X-OVER in HPF, ROUTE in L/R
Example 4:
Eight 4 ohm ceiling speakers working in
mono for four environments:
CH3/CH4: X-OVER in HPF, ROUTE in L+R
CH1/CH2: X-OVER in HPF, ROUTE in L+R
NOTE:
The THS 6000 does not allow two signal
sources to operate at the same time, known as dual
zone.
Examples of connections/configurations
AMBIENTE 3
AMBIENTE 2
TOTAL: 100RMS MONO
TOTAL: 100RMS MONO
4 ohms
200W RMS
R
SALA 2
4 ohms
200W RMS MONO
TOTAL: 200RMS STEREO
AMBIENTE 1
TOTAL: 100RMS MONO
11
4 ohms
4 ohms
200W RMS
L
SALA 1
4 ohms
4 ohms
4 ohms
200RMS STEREO
TOTAL: 400RMS
STEREO
TOTAL: 200RMS STEREO