CAUTION: All connections to power supply, input and output connectors must be
carried out only with amplifier off.
Installation
Recommended wire gauge & fuse
11
*Illustrative images
Remote Cable 18 AWG
11 A
WG
2,5mm² (13 A
WG)
RCA Cable
Taramps
Head Unit
12V
GND
Wire Input:
If you choose to use this input, you won’t
need to connect the RCA’S cable and
remote signal.
11 A
WG
Three way box
1,5mm² (15 A
WG)
1,5mm² (15 A
WG)
LOW OUT
HIGH OUT
MID OUT
Note:
The 400 TRIO has a built - in passive filter for in each MID and HIGH outs..
Remote cable ___________________
_________________________________ 18 AWG
Check polarity and never reverse power supply cables due to the risk of damage to the
amplifier.
Output cables wire gauge (LOW OUT) ___________________
______________13 AWG
Positive / negative power supply cable _________________
_______________ 11 AWG
Output cables wire gauge (MID OUT / HIGH OUT) ___________________
____ 15 AWG
Protection fuse or circuit breaker
________________________________________ 20A
Wire gauge calculated based in a 13,12 feets maximum lenght. For greater distances,
increase the cable gauge to avoid power losses.
Caution: Using wire gauges below the recommendation will result in power loss and
overheating of wiring.
It is compulsory to install a protection fuses or circuit breakers as close as possible from
batteries.