10
805-0039C Rev F
E.
Insert the lubricated replacement O-ring, PN 208-5003, over the plunger stem and install into
the bottom of the gland using the PN 316-0028 O-ring insert tool,
Fig. 16
.
Fig. 16
F.
Replace the retainer(s) by aligning the holes over the stem plunger and slide down onto
the handle, see
Fig. 17
.
The oval divots in PN 266-0329 are designed to face towards the center of the handle, see
Fig. 18.
However, orientation of the retainers is only critical on 14B handles (266-0361
retainer), which is why there is an up arrow indicating the proper orientation, see
Fig. 12
.
Fig. 17
Fig. 18
NOTE:
Failure to shut off flow to the handle may result in a high-pressure blast of water or
syrup to be shot out of the o-ring gland if plunger stem is accidentally depressed.
Oval divots