3.
MAINTENANCE
IOM manual Tapflo PTL Hose pumps
36
53
Fig. 3.13.5
Fix the shaft [16] with the smaller circlip [53] by placing it in the shaft groove.
3.14.
Casing assembly directions
The standard pump configuration includes casing directed to the right. However, other positions
are also possible.
Fig. 3.14.1
Left direction; standard casing direction
Fig. 3.14.2
Right direction; the pump is designed in
such a way that it can be easily directed to the righ
without any modifications. By using the code
“
2
”
when ordering the pump, the housing will be
installed in the right direction.
Fig. 3.14.3
Upwards direction; directing casing upwards requires certain modifications that need to be made at
the ordering stage. Use the code
“
2U
”
for such a configuration.
NOTE!
This position is not recommended for fluids with solid particles due to the possibility of their
accumulation in the hose due to gravity.
NOTE!
Due to the increased risk of hose rupture, directing the housing upwards is not permitted in potentially
explosive athmospheres (ATEX).