![TapFlo PTL Series Manual Download Page 30](http://html2.mh-extra.com/html/tapflo/ptl-series/ptl-series_manual_4371279030.webp)
3.
MAINTENANCE
IOM manual Tapflo PTL Hose pumps
29
Fig. 3.9.6
Disconnect power form the motor and once again
remove the front connection bracket [170F].
Fig. 3.9.7
Remove the hose [15] along with the inserts [70] and
clamp bands [271].
Fig. 3.9.8
Remove the clamp bands [271] and the inserts [70]
form the hose.
Clean the inserts [70] and pump casing [11].
Fig. 3.9.9
Clean the new hose [15] thoroughly before assembly.
Assemble the new hose with inserts [70] and tighten
the clamp bands [271].
Fig. 3.9.10
Place the hose [15] inside the pump casing.
Fig. 3.9.11
Align the inserts with the rear connection bracket
[170R].
170F
15
271
70
15
271
70
70
170