3.4. Air Motor – Flushing 

Flush the motor if it is operating slowly or inefficiently. Flushing the air motor removes 

excessive dirt,  foreign particles, moisture or oil that occurs  in the operating 

environment and will help to maintain proper vane performance/motor efficiency. 

Safety - Flush the air motor in a well ventilated area. Keep face away from exhaust port. 

Eye protection must be worn. 

Use Gast # AH255B Flushing Solvent, or  any non-toxic, non-flammable industrial 

cleaning solvent. 

DO NOT

 use paraffin or 

ANY

 other combustible solvents to flush this 

air motor. 

 

3.5. Material Disposal 

Tapflo IBC mixers series LBC, HBC are designed for a long trouble-free life. At the end of 

the useful service life the lubricants and components can be recycled. 

The IBC mixer, frame, shaft and impeller are manufactured from stainless steel and the 

gearbox and electric motor from aluminium and cast iron. 

Properly dispose of all mixer and gearbox parts responsibly, in particular lubricants

 

which must be  collected for disposal or recycling  in accordance with local authority 

guidelines. 

 

3.6. Ordering Spare Parts 

To maintain your IBC mixer only Tapflo  genuine spare parts are recommended. To 

ensure safe  reliable operation of your mixer please contact your local distributor for 

spare parts. 

To order please state: 

Serial number – indicated on the mixer nameplate. 

Item number – description of the part and quantity. 

 

 

 

 

 

 

 

 

 

 

 

 

 

Summary of Contents for LBC Series

Page 1: ...IOM Manual IBC Mixers Mixers LBC HBC 3 IBC Mixers Series LBC HBC Edit 2022 IOM manual Read this instruction manual carefully before you install and operate the pump...

Page 2: ...2 3 Fault Diagnosis 3 Maintenance 3 1 Routine Maintenance 3 2 Lubrication 3 3 Tightening Torques 3 4 Air motor Flushing 3 5 Material Disposal 3 6 Ordering Spare Parts 4 Supplementary Instructions and...

Page 3: ...IOM Manual IBC Mixers Mixers LBC HBC 3...

Page 4: ...ler Blank Std Impeller Fixed impeller for HBC folding impeller for LBC E Std Impeller F 280 fixed impeller 280mm diameter F Std Impeller F 300 fixed impeller 300mm diameter G Std Impeller F 320 fixed...

Page 5: ...ency inverter E External frequency inverter 6 Optional frame connection Blank none H Hopper for powders L Liquid inlet 7 Lifting arrangement Blank Standard lifting frame with eye bolt F Forklift modul...

Page 6: ...on an IBC and a 16 AMP appliance Inlet plug protection IP44 splash proof The mixer drive is supported on a lightweight stainless steel bridge which mounts directly onto the IBC and is held in place w...

Page 7: ...or starter voltage requirements correspond with the supply or verify if compressed air supply system is suitable in case of mixer with air motor 2 Check that the mixer shaft direction of rotation corr...

Page 8: ...mpressed air supply can be connected if safe to do so 9 After use before moving the mixer isolate from the power supply and disconnect the lead to the appliance plug In case of an air motor it should...

Page 9: ...wrong direction Check that the direction of rotation corresponds with the arrow on the mixer nameplate Rotation is clockwise when viewed from above All drives Impeller rotating in the wrong direction...

Page 10: ...t higher SG or viscosity product being mixed Contact Tapflo or your local distributor for advice Electric drive Motor starts but has low torque or does not reach full speed 3 phase motor is single pha...

Page 11: ...ations in the UK BGV A3 in Germany or local site codes of practice as applicable 3 2 Lubrication Electric motor bearings are sealed for life and do not require any maintenance or re lubrication The ge...

Page 12: ...isposal Tapflo IBC mixers series LBC HBC are designed for a long trouble free life At the end of the useful service life the lubricants and components can be recycled The IBC mixer frame shaft and imp...

Page 13: ...2 25 Switch plate 1 7 Lifting strap 1 26 Spring operating block 1 8 Lifting eyebolt 1 27 Spring 1 9 Gasket 1 28 Cable gland 6 10 Appliance inlet 1 29 Cable covering 1 11 Hex socket head setscrew 2 30...

Page 14: ...3 Mounting Frame 1 30 Nameplate 1 4 Drive Coupling 1 32 Hex head screw 2 5 Hexagon socket set screw 4 33 Hexagon nut 2 6 Quick action toggle clamps 2 34 Hex head screw 4 7 Lifting strap 1 35 Hexagon n...

Page 15: ...equired in the supply line Adjust the air line lubricator to 1 drop of oil per minute Regulate the line pressure to 7 bar max Noise air motors are supplied with the standard muffler on the exhaust air...

Page 16: ...level radial flow fixed impeller can also be supplied for mixing the IBC contents at very low liquid levels install below the folding impeller as illustrated A 1000mm long shaft is available with thi...

Page 17: ...e needs of the Customer except for those purposes set out in any invitation to render documents or other documents specifically made available to Tapflo before entering into this agreement c high qual...

Page 18: ...nt under the terms of this warranty shall not give a right to an extension to or a new commencement of the period of warranty 6 Repair or replacement under the terms of this warranty shall not give a...

Page 19: ...IOM Manual IBC Mixers IBC Mixers LBC HBC 19...

Reviews: