IOM manual Active pulsation dampeners 

1.5.1. 

Protection

In the interest of health and safety it is essential to wear protective clothing and safety goggles 

when operating, and/or working in the vicinity of Tapflo dampeners.

1.5.2. 

Explosion hazardous environments – ATEX

Static electricity may occur in the pump under operation, which may cause explosion 
and injury. Special conductive pulsation dampeners DTX are available for such applications.  
Follow below instructions and local/national rules for safe use. 

ATEX (directive 94/9/EC) classification of Tapflo DTX dampeners:

ATEX 

II 2 GD

 

IIB

 

c

 

T4

Equipment group 

II

 – all other explosive areas than mines; 

Category group 

2

 – high level of protection (can be used in zone 1);

Atmosphere 

G

 – gas; 

D

 – dust;

Explosion group 

IIB

 – such as ethylene;

Type of protection 

c

 – constructional safety;

Temperature class 

T4

 – in the event of a malfunction, the maximum temperature of a surface that 

may be exposed to gas T4 = 135 °C.

Earth connection of dampener and other equipment 

Connect a suitable earth wire to the stainless steel earth connection that is placed on the inside 

of one of the pump housings. Connect the other end of the earth wire to earth and also make sure 

that other equipment like hoses/pipes/containers etc. are properly earthed/connected.

1.5.3. 

Air pressure

The maximum air pressure for Tapflo dampeners is 14 bar. Higher air pressure than 14 bar can 

damage the dampener and may cause injury to personnel in vicinity of the dampener. 

Please make sure that supply air to the dampener must have the same flow and pressure as the 

pump that dampener is installed with.

1.5.4. 

Noise level

At tests, the noise level from a Tapflo dampener has not exceeded 70 dB(A).

1.5.5. 

Temperature hazards

Raised temperature can cause damage to the dampener and/or piping and may also be hazar-

dous for personnel in the vicinity of the dampener/piping. Avoid quick temperature changes and 

do not exceed the maximum temperature specified when the dampener was ordered.

1. 

INSTALLATION & SAFETY

STOP

STOP

STOP

Summary of Contents for DT Series

Page 1: ...for active pulsation dampeners STOP Read this instruction manual carefully before you install and operate the pump Active pulsation dampeners models DT 9 20 25 DT 50 70 80 DT 100 120 125 DT 200 220 22...

Page 2: ...NANCE 8 2 1 When dampener is new or re assembled 8 2 2 Routine inspection 8 2 3 Location of faults 8 2 4 Dismantling of the dampener 8 2 5 Assembling the dampener 10 3 SPARE PARTS 13 3 1 Spare parts d...

Page 3: ...lares that Product name Active Pulsation Damener Models D T Is in conformity with the essential health and safety requirements and technical construction requirements of the EC Machinery directive 200...

Page 4: ...installing operating and maintaining the dampener 0 2 The warning symbols The following warning symbols are present in this instruction manual This is what they say This symbol stands next to all saf...

Page 5: ...e pulsation dampener is installed according to the sketch It can be connected with a nipple im mediately after the pump outlet or placed independent of the pump with a flexible hose between the pump a...

Page 6: ...ampeners block works as a spring for the medium flowing through the dampener Before starting the pump and dampener Make sure the pump is installed according to the installation instruction When instal...

Page 7: ...that may be exposed to gas T4 135 C Earth connection of dampener and other equipment Connect a suitable earth wire to the stainless steel earth connection that is placed on the inside of one of the pu...

Page 8: ...of wear Leakage of liquid from the dampener and changes in performance may also be detected Routine inspections should be conducted frequently 2 3 Location of faults PROBLEM POSSIBLE FAULT The dampene...

Page 9: ...ut alongside with the washers 38 Fig 2 4 4 Take out the dampener block 12 Fig 2 4 5 Take the pin screws 14 out of the dampener housing 11 Fig 2 4 6 Unscrew the diaphragm 15 by hand clockwise Fig 2 4 7...

Page 10: ...e dampener block 12 To make the procedure easier bend the seals into a kidney shape and then fit them with a screwdriver Fig 2 5 3 Push the shaft 1651 into the dampener block 12 Check all components a...

Page 11: ...e shaft ending 1652 onto the shaft 1651 Note When the diaphragm is screwed in the holes in the diaphragm must be aligned with the holes in the block Fig 2 5 6 Push the diaphragm 15 in so that it is to...

Page 12: ...4 from the side of the block and pre tighten the nuts cross side Fig 2 5 11 Tighten the nuts 37 cross side by means of a torque wrench with the appropriate torque see chapter 4 2 Fig 2 5 12 Insert the...

Page 13: ...Threaded insert 4 1173 Reinforcement plate 1 1181 Cover 1 12 Dampener block 1 14 Pin screw 4 6 8 15 Diaphragm 1 1651 Shaft 1 1652 Ending for shaft 1 17 option Base 1 174 option Socket head cap screw 4...

Page 14: ...7 25 579 37 38 12 1651 1652 90 14 47 36 15 11 142 37 38 175 174 POS DESCRIPTION QUANTITY 11 Dampener housing 1 12 Dampener block 1 14 Pin screw 4 6 8 142 Washer 4 6 8 15 Diaphragm 1 1651 Shaft 1 1652...

Page 15: ...order to avoid expensive breakdowns we recommend having a few spare parts in stock These are 3 6 How to order parts When ordering spare parts for Tapflo dampeners it will simplify the process if you...

Page 16: ...A P G K B I B L C D A P PE PTFE and aluminium dampener Dimensions in mm where other is not indicated Dimensions in inch where other is not indicated Steel and sanitary dampener 1 PE PTFE 2 ALU SS 3 IS...

Page 17: ...ecutions Changes reserved without notice 9 20 30 50 80 100 125 200 225 400 425 800 825 DIN Flange 955 954 955 1054 1155 1154 1505 1504 1655 1654 2025 2004 ANSI 89 6 907 896 1007 1086 1107 1276 1257 15...

Page 18: ...that machining and as sembly are carried out to the highest standards Except as expressly stated above Tapflo makes no warranties express or implied concerning the products including all warranties o...

Page 19: ...hey need to be adapted changed or adjusted to conform to national or local technical or safety standards in force in any country other than that for which the unit was originally designed and manufact...

Page 20: ...ype Serial No stamped on the dampener housing Description of the fault The installation Liquid Temperature C Viscosity cPs Spec grav kg m3 pH value Contents of particles of max size mm Flow l min Duty...

Page 21: ...IOM manual Active pulsation dampeners 21 NOTES...

Page 22: ...e perfect choice for your pumping needs Tapflo Fluid Handling India Private Limited Office No 207 Amar Neptune Baner Pune 411045 INDIA Phone 91 20 65000215 E mail ad tapflo in Web www tapflo in Kung l...

Reviews: