Instruction manual CTV vertical pumps
18
5. DATA
Changes reserved without notice
5.2
Technical data
5.2.1
Data PP & PVDF pumps
Dimensions in mm, where other is not indicated
General characteristics
25-9
25-10
25-11
25-11.5
32-8.5
32-10
32-12.5
Max capacity (m
3
/h)
10.2
13.2
15.6
18.0
19.8
24.0
27.0
Max head (m)
10
14
16
19
10
17
23
Motor power (kW)
0.55
0.75
1.1
1.5
1.1
1.5
2.2
Outlet dimension (male BSP)
1”
1”
1”
1”
1 1/4”
1 1/4”
1 1/4”
Motor data
3-phase, 2-pole (~2900 rpm), 380-420 VAC, 50 Hz, IP 55
Max temperature
Pump in PP: 70°C, pump in PVDF: 100°C
Materials
Pump casing and impeller
PP or PVDF
Casing o-ring
EPDM, FKM or FEP
Dimension
CTV 25
CTV 32
A
285
285
B
200
200
E
85
85
F
56
56
G
95
95
H
1”
1 1/4”
J
25
25
K
419
419
L
123
126
M
60
60
N
1”
1 1/4”
Motor power
D
I
0.55 kW
196
213
0.75-2.2 kW
214
267