4.
OPTIONS
IOM manual CTI & CTH centrifugal pumps
32
4.7.
Semi-open impeller – 4H; Reinforced impeller – 4W
Tapflo CT pumps can be fitted with a semi-open impeller in comparison to
its standard open impeller. This option ensures more stable operation, lower
noise, lower vibrations and more robust construction. It is recommended to
use the semi-open impeller when hard solids can be present in the pumped
liquid. This impeller is always in reinforced execution.
The reinforced impeller is a great option when pumping high viscous
liquids or ones containing solid particles. This design is much more robust
and can withstand more tensions transferred from the liquid.
NOTE! The D, F and G size impellers are reinforced as standard.
Additional / different parts:
Available for all pump sizes
Art. no
Q-ty
Description
5-xxx-9xxxH
1
Semi-open impeller
5-xxx-16W
1
Reinforced shaft
5-xxx-191W
1
Domed nut for impeller
5-xxx-192
1
Washer
5-xxx-193
1
Mounting key
Art. no
Q-ty
Description
5-xxx-16W
1
Reinforced shaft
5-xxx-9xxxW
1
Reinforced impeller
5-xxx-191W
1
Domed nut for impeller
5-xxx-192
1
Washer
5-xxx-193
1
Mounting key