background image

L E G A L   N O T I C E S  

This Guide, and any associated software, is being provided to you only as a licensee pursuant to legal agreements with 
Tantalus Systems Corp. that govern your rights and all other aspects of the relationship, and prevail over the legal notices 
herein to the extent of any inconsistency.  

INFORMATION SUBJECT TO CHANGE The products and methods described in this Guide are the subject of continuous 
development and so the information contained herein may change without notice. 

REGULATORY AND SAFETY The products and methods described in this Guide are to be handled and/or performed 
only by properly trained personnel who understand and strictly follow the instructions of this Guide, including all the 
regulatory and safety rules. Failure to so follow may void your legal remedies and regulatory authorizations, amongst 
other legal effects. 

INTELLECTUAL PROPERTY 

Copyright Notice  © 2011 Tantalus Systems Corp. All rights reserved.  

The copyright notice on this Guide does not indicate any actual or intended publication of any confidential information or 
trade secrets contained in or embodied by any associated software.  

No part of this Guide, or any associated software, may be reproduced, adapted, translated, stored, or transmitted in any 
form or by any means except with prior written permission of Tantalus Systems Corp. or as explicitly allowed by copyright 
laws applicable to your situation. This Guide contains proprietary information of Tantalus Systems Corp. that may be 
disclosed only to your permitted contractors and customers who need to know. 

Trademarks  Tantalus, TUNet, Tantalus Utility Network, the stylized T logo, and the names of the products and services 
offered therewith, are trademarks of Tantalus Systems Corp. All other product and brand names referenced herein may 
be trademarks of their respective owners. 

Patents  The information and technology described in this Guide, and any associated products, methods, or software, 
may be the subject of patents and pending applications of Tantalus Systems Corp. and/or its licensees. 

WARRANTY   
LIMITATION OF LIABILITY. THE INFORMATION IN THIS GUIDE IS PROVIDED "AS IS" WITH NO WARRANTY 
WHATSOEVER AND TANTALUS SYSTEMS CORP. SPECIFICALLY DISCLAIMS ANY WARRANTIES, CONDITIONS, 
OR REPRESENTATIONS (EXPRESS OR IMPLIED, ORAL OR WRITTEN) WITH RESPECT TO THE GUIDE OR ANY 
PART THEREOF, INCLUDING ANY OR ALL WARRANTIES, CONDITIONS OR REPRESENTATIONS OF TITLE, 
MERCHANTABILITY, NON-INFRINGEMENT FITNESS FOR A PARTICULAR PURPOSE (WHETHER OR NOT 
TANTALUS SYSTEMS CORP. KNOWS, HAS REASON TO KNOW, HAS BEEN ADVISED, OR IS OTHERWISE IN 
FACT AWARE OF ANY SUCH PURPOSE), WHETHER ALLEGED TO ARISE BY LAW, EQUITY, STATUTE OR 
GOVERNMENTAL POLICY, BY REASON OF CUSTOM OR USAGE IN THE TRADE, OR BY COURSE OF DEALING. IN 
NO EVENT WILL TANTALUS SYSTEMS CORP. BE LIABLE FOR ANY DAMAGES OR COSTS WHATSOEVER OR 
ANY SPECIAL, INDIRECT, PUNITIVE, INCIDENTAL AND CONSEQUENTIAL DAMAGES, OR ANY LOST PROFITS OR 
LOST SAVINGS, EVEN IF IT HAS BEEN ADVISED OF THE POSSIBILITY THEREOF. THE AGGREGATE LIABILITY 
OF TANTALUS SYSTEMS CORP. AND ITS REPRESENTATIVES (INCLUDING ITS EMPLOYEES, OFFICERS, 
DIRECTORS, AGENTS, LICENSORS, DISTRIBUTORS AND SUPPLIERS) IN CONNECTION WITH THIS GUIDE 
(WHETHER IN TORT, CONTRACT OR OTHERWISE) IS LIMITED ACCORDING TO THE GOVERNING LEGAL 
AGREEMENTS. THESE LIMITATIONS SHALL APPLY WHETHER OR NOT THERE IS A FUNDAMENTAL BREACH OF 
CONTRACT. SOME JURISDICTIONS CURTAIL OR PROHIBIT LIMITATIONS OF LIABILITIES, AND THEREFORE THE 
ABOVE LIMITATIONS MAY NOT APPLY TO YOUR SITUATION. 

EXPORT CONTROL  Export of this Guide and its information may be controlled by the laws of the United States of 
America, Canada and the laws that govern you. Export in contravention of such laws is strictly prohibited.  

S A F E T Y   N O T I C E  

 

 

Warning 

Energized meters, meter sockets and distribution lines present the risk of electrical shock. 
All work on this equipment should be performed by qualified metering specialists or 
industrial electricians. 

Personnel working with this equipment should follow all utility company established 
operation and safety procedures. 

Summary of Contents for ITRON SENTINEL TUNet PP-1316

Page 1: ...INSTALL GUIDE TUNet PP 1316 Sept 18 2011 KT 109967 Tantalus Systems Corp 301 3480 Gilmore Way Burnaby BC V5G 4Y1 Canada p 604 299 0458 f 604 451 4111 www tantalus com ITRON SENTINEL METER READER ...

Page 2: ...methods or software may be the subject of patents and pending applications of Tantalus Systems Corp and or its licensees WARRANTY LIMITATION OF LIABILITY THE INFORMATION IN THIS GUIDE IS PROVIDED AS IS WITH NO WARRANTY WHATSOEVER AND TANTALUS SYSTEMS CORP SPECIFICALLY DISCLAIMS ANY WARRANTIES CONDITIONS OR REPRESENTATIONS EXPRESS OR IMPLIED ORAL OR WRITTEN WITH RESPECT TO THE GUIDE OR ANY PART THE...

Page 3: ...Under Industry Canada regulations this radio transmitter may only operate using an antenna of a type and maximum or lesser gain approved for the transmitter by Industry Canada To reduce potential radio interference to other users the antenna type and its gain should be so chosen that the equivalent isotropically radiated power e i r p is not more than that necessary for successful communication R ...

Page 4: ... Product Specification PP 1316 C I Meter Reader 2 2 Installing the PP 1316 3 2 1 Equipment Required 3 2 2 Installing PP 1316 Components 4 2 2 1 Installing PP 1316 Components into the Itron SENTINEL Meter 5 2 3 Configuring the Meter 9 3 Contact Information 10 ...

Page 5: ...stom date and time as commanded by the TUNet Network Server at Peak Demand Reset provide non coincident peak kW kVAR kVA as calculated by the Sentinel meter kW kVAR and kVA intervals for trending and profiling purposes voltage on all phases upon request or by interval Upon request o co incident values to the peaks kW kVA kVAR if configured in the meter o cumulative kWh kVAh kVARh o the current val...

Page 6: ...t Operating Temperature 22 to 140 F 30 to 60 C Modulation FSK Power Consumption Active Power 2 watts Operating Humidity 5 to 95 non condensing 900 MHz Antenna Part 15 Antenna within sealed meter not accessible to installer operator Standards FCC CFR Title 47 Part 15c Intentional Radiators ANSI C12 1 2008 Compliant CFR Title 47 Part 15b Unintentional Radiators ...

Page 7: ... All work on this equipment should be performed by qualified metering specialists or industrial electricians Personnel working with this equipment should follow all utility company established operation and safety procedures 2 1 Equipment Required The following equipment is required to program the Itron SENTINEL Meter socket or equivalent to power up the meter to be programmed ANSI Type 2 optical ...

Page 8: ...s e m b l i e s The PP 1316 is compatible with all Itron SENTINEL meter forms The following parts are supplied with the PP 1316 installation kit 1 Tantalus communication module P N 120 0215 2 Tantalus antenna bracket P N 260 0055 P P 1 3 1 6 C o m p o n e n t s L i s t S i n g l e A s s e m b l y 1 Tantalus communication module P N 120 0215 A ...

Page 9: ... 1 Remove the outer plastic cover from the Itron SENTINEL 2 Unclip the Itron SENTINEL display housing from its base by gently lifting the snap features in two locations 3 Slightly tilt the display housing away from the base to disengage the two pieces 4 Locate the set of four parallel ridges inside the display housing ...

Page 10: ...dges 6 Firmly press the ribbon cable connector against the mating header underneath the Itron SENTINEL communications board To ensure proper connectivity verify that the ribbon cable connector is inserted as shown in the following figure Note If the connector was not engaged properly there will be a visible row of crimps on the blue ribbon cable connector as shown in the following figure ...

Page 11: ... the display housing Ensure that the clip on the top of the display housing is used to lock down the PP 1316 module 8 Ensure that the coaxial cable falls within the hole on the side of the display housing 9 Snap the display housing back on the base of the meter Ensure that all four outer snaps are engaged ...

Page 12: ...t on the top of the meter Also there is a clip on the side of the bracket which guides the coaxial cable Ensure the coaxial cable is placed inside the clip If the coaxial cable has SMA RF connectors mate them together 11 Place the outer cover back over the Itron SENTINEL meter ...

Page 13: ...TUNet PP 1316 Install Guide page 9 Doc No KT 109967 2 3 Configuring the Meter TBD ...

Page 14: ...11 3 Contact Information T a n t a l u s S y s t e m s C o r p Tantalus Systems Corp 301 3480 Gilmore Way Burnaby BC Canada V5G 4Y1 T 604 299 0458 F 604 451 4111 TECHNICAL SUPPORT TantalusTechSupport tantalus com GENERAL ENQUIRIES Info tantalus com ...