background image

 

INSTALL GUIDE

 

TUNet

®

 

PP-1316

 

Sept 18, 2011 

KT-109967 

Tantalus Systems Corp.

 

301– 3480 Gilmore Way Burnaby BC V5G 4Y1 Canada 
p 604.299.0458 | f 604.451.4111  
www.tantalus.com

 

 

 

ITRON SENTINEL

®

 METER 

READER 

 
 
 

Summary of Contents for ITRON SENTINEL TUNet PP-1316

Page 1: ...INSTALL GUIDE TUNet PP 1316 Sept 18 2011 KT 109967 Tantalus Systems Corp 301 3480 Gilmore Way Burnaby BC V5G 4Y1 Canada p 604 299 0458 f 604 451 4111 www tantalus com ITRON SENTINEL METER READER ...

Page 2: ...methods or software may be the subject of patents and pending applications of Tantalus Systems Corp and or its licensees WARRANTY LIMITATION OF LIABILITY THE INFORMATION IN THIS GUIDE IS PROVIDED AS IS WITH NO WARRANTY WHATSOEVER AND TANTALUS SYSTEMS CORP SPECIFICALLY DISCLAIMS ANY WARRANTIES CONDITIONS OR REPRESENTATIONS EXPRESS OR IMPLIED ORAL OR WRITTEN WITH RESPECT TO THE GUIDE OR ANY PART THE...

Page 3: ...Under Industry Canada regulations this radio transmitter may only operate using an antenna of a type and maximum or lesser gain approved for the transmitter by Industry Canada To reduce potential radio interference to other users the antenna type and its gain should be so chosen that the equivalent isotropically radiated power e i r p is not more than that necessary for successful communication R ...

Page 4: ... Product Specification PP 1316 C I Meter Reader 2 2 Installing the PP 1316 3 2 1 Equipment Required 3 2 2 Installing PP 1316 Components 4 2 2 1 Installing PP 1316 Components into the Itron SENTINEL Meter 5 2 3 Configuring the Meter 9 3 Contact Information 10 ...

Page 5: ...stom date and time as commanded by the TUNet Network Server at Peak Demand Reset provide non coincident peak kW kVAR kVA as calculated by the Sentinel meter kW kVAR and kVA intervals for trending and profiling purposes voltage on all phases upon request or by interval Upon request o co incident values to the peaks kW kVA kVAR if configured in the meter o cumulative kWh kVAh kVARh o the current val...

Page 6: ...t Operating Temperature 22 to 140 F 30 to 60 C Modulation FSK Power Consumption Active Power 2 watts Operating Humidity 5 to 95 non condensing 900 MHz Antenna Part 15 Antenna within sealed meter not accessible to installer operator Standards FCC CFR Title 47 Part 15c Intentional Radiators ANSI C12 1 2008 Compliant CFR Title 47 Part 15b Unintentional Radiators ...

Page 7: ... All work on this equipment should be performed by qualified metering specialists or industrial electricians Personnel working with this equipment should follow all utility company established operation and safety procedures 2 1 Equipment Required The following equipment is required to program the Itron SENTINEL Meter socket or equivalent to power up the meter to be programmed ANSI Type 2 optical ...

Page 8: ...s e m b l i e s The PP 1316 is compatible with all Itron SENTINEL meter forms The following parts are supplied with the PP 1316 installation kit 1 Tantalus communication module P N 120 0215 2 Tantalus antenna bracket P N 260 0055 P P 1 3 1 6 C o m p o n e n t s L i s t S i n g l e A s s e m b l y 1 Tantalus communication module P N 120 0215 A ...

Page 9: ... 1 Remove the outer plastic cover from the Itron SENTINEL 2 Unclip the Itron SENTINEL display housing from its base by gently lifting the snap features in two locations 3 Slightly tilt the display housing away from the base to disengage the two pieces 4 Locate the set of four parallel ridges inside the display housing ...

Page 10: ...dges 6 Firmly press the ribbon cable connector against the mating header underneath the Itron SENTINEL communications board To ensure proper connectivity verify that the ribbon cable connector is inserted as shown in the following figure Note If the connector was not engaged properly there will be a visible row of crimps on the blue ribbon cable connector as shown in the following figure ...

Page 11: ... the display housing Ensure that the clip on the top of the display housing is used to lock down the PP 1316 module 8 Ensure that the coaxial cable falls within the hole on the side of the display housing 9 Snap the display housing back on the base of the meter Ensure that all four outer snaps are engaged ...

Page 12: ...t on the top of the meter Also there is a clip on the side of the bracket which guides the coaxial cable Ensure the coaxial cable is placed inside the clip If the coaxial cable has SMA RF connectors mate them together 11 Place the outer cover back over the Itron SENTINEL meter ...

Page 13: ...TUNet PP 1316 Install Guide page 9 Doc No KT 109967 2 3 Configuring the Meter TBD ...

Page 14: ...11 3 Contact Information T a n t a l u s S y s t e m s C o r p Tantalus Systems Corp 301 3480 Gilmore Way Burnaby BC Canada V5G 4Y1 T 604 299 0458 F 604 451 4111 TECHNICAL SUPPORT TantalusTechSupport tantalus com GENERAL ENQUIRIES Info tantalus com ...

Reviews: