background image

Damage to equipment can be caused by:

• external forces;

• corrosion;

• chemical action;

• erosion;

• material exhaustion;

• water hammer;

• thermal and/or mechanical shock;

• freezing;

• wrong transport/lifting.

If a danger of frost occurs, the tank and the coil(s) should be drained completely.

Sudden pressure and temperature changes should be prevented.

Even after stopping the installation some parts of it can still be hot!  Therefore, it must be allowed to 

cool down to intervene.

If welding activities have to be carried out near the equipment, never use the tank for earthing.

Electric currents can cause severe damage to product.

If you have to weld, dismantle the connections and isolate the equipment from the system.

When a tank (filled with water or water mixture) which is not in operation is exposed to 

temperatures below zero, the tank can be damaged.

The water heater coils are only suitable for hot water or water-glycol mixtures in the liquid 

phase.  In the coils, steam and superheated water cannot be used as heating medium.

Potable water with a hardness of 20 Fr and above should not be used in a storage water heater 

without reducing its hardness.  Otherwise, lime deposits formed on hot coil surfaces both reduce 

the equipment's heating capacity by preventing heat transfer and may cause perforation on the 

overheated coil surfaces due to corrosion.

The chemical and physical nature of the water to be heated and stored in the tank must comply 

with the limit values specified in the Council directive 98/83/EC of 3 November 1998 on the quality 

of water intended for human consumption.

We reserve the right to make changes in technical information. 

4

Summary of Contents for TDB Series

Page 1: ...www tanpera com STORAGE WATER HEATER TSB and TDB Series DOMESTIC HOT WATER STORAGE TANK PRO Series INSTALLATION OPERATION AND MAINTENANCE MANUEL...

Page 2: ...e of printing However because of rapid developments in this field we cannot be held liable for changes in specifications affecting the contents of this publication COPYRIGHT Copyright Tanpera A All ri...

Page 3: ...er heater 5 2 PRO series domestic hot water storage tank 6 INSTALLATION 6 1 Siting 6 2 Space requirements for the installation location 6 3 Transport lifting storage 6 4 Installing the pipe connection...

Page 4: ...s and regulations are strictly kept concerning human environment protection YELLOW TRIANGLE Refer to applicable SAFETY ALERT notices within the manuel All SAFETY ALERT notices are applicable to person...

Page 5: ...ified Type key Type code TSB Single pipe coil storage water heater TDB Double pipe coil storage water heater PRO Hot water storage tank Total storage capacity liters Nominal operating pressure bar TSB...

Page 6: ...be put into operation before all indistinctnesses have been solved To avoid injuries and damages follow the instructions and local applicable safety regulations Also take the necessary protective meas...

Page 7: ...th water or water mixture which is not in operation is exposed to temperatures below zero the tank can be damaged The water heater coils are only suitable for hot water or water glycol mixtures in the...

Page 8: ...the hot water circulated in the coil The domestic hot water supply values given in the catalog are valid if the heating water inlet temperature and the flow rate corresponding to the capacity specifie...

Page 9: ...information 6 Hot water exit Heating inlet Hot water return Heating exit Heating inlet Heating exit Capacity 100 5000 liters Designated use Hot water not exceeding 90 C Operation pressure 10 bar Mount...

Page 10: ...drainage system floor drain sump pit and pump etc capable of discharging water should be provided on the floor TANPERA shall not be liable for water leak damages that may be caused by the product or t...

Page 11: ...nges in technical information 8 To lift the unit itself first remove the thermoplastic cap on top and expose the transport eyebolts Particularly for the tanks with steel sheet sleeve care must be take...

Page 12: ...with original packaging in a closed place which is absolutely free of external weather conditions Rising of the unit The pallet should be removed before mounting To remove the pallet lay down the uni...

Page 13: ...technician We reserve the right to make changes in technical information 10 Before filling the tank with water unused connection ports should be blocked with a blind plug Electrical control panel must...

Page 14: ...k is completely filled with water check all connections and piping for leaks This control can be made by visual inspection or by monitoring the pressure drop from the manometer in the installation Com...

Page 15: ...perform cleaning and periodic maintenance of your product During cleaning and maintenance tools and chemicals that may cause physical and chemical damage to the enamel should not be used Maintenance...

Page 16: ...arranty period are excluded from the warranty if it is detected that the magnesium anode is fully depleted Install the anode in place and tighten it Open the cold water valve and continue to use the p...

Page 17: ...es Clean the strainer filter at the cold water inlet Turbid water flowing from taps Anode is depleted or not functioning Water leakage from the unit Flange or anode seal defective Safety valve opening...

Page 18: ...e anode Replace if finished Call TANPERA service if the problem is not resolved Tank dirty Safety valve opening Unable to compensate water expansion Safety valve opening pressure is low Pressure incre...

Page 19: ...at hasn t been authorised by TANPERA c Products that commissioning is required but are not commissioned by our After Sales Services Department or by a service organization authorized by us d Defects r...

Page 20: ...S WITH INDIRECT PIPE COIL ELECTRIC STORAGE WATER HEATERS DOMESTIC HOT WATER STORAGE TANKS PACKAGE TYPE DOMESTIC HOT WATER SYSTEMS BUFFER TANKS EXPANSION TANKS DEAERATORS DIRT SEPERATORS HYDROLIC SEPER...

Reviews: