Specifications 

OCV 8

OCV 6

Performance

Frequency Response (-3 dB) 

(1)

75 Hz - 20 kHz

80 Hz - 20 kHz

Frequency Range (-10 dB) 

(1)

60 Hz - 30 kHz

System Sensitivity (1 W @1 m) 

(2)

90 dB

88 dB

Dispersion (-6 dB)

80 degrees conical

90 degrees conical

Transducers 

Coaxial

Low Frequency

200 mm (8.00") mineral loaded cone material

150 mm (6.00") mineral loaded cone material

High Frequency

25 mm (1.00")

20 mm (0.79)

Crossover

4.5 kHz - 3rd order LF, 2d order HF

5.4 kHz - 2nd order LF, 2nd order HF

Directivity (Q)

14.4 averaged 1 kHz to 6.3 kHz

11.3 averaged 1 kHz to 6.3 kHz

Directivity (DI) 

11.6 dB averaged 1 kHz to 6.3 kHz

10.5 dB averaged 1 kHz to 6.3 kHz 

Rated Maximum SPL

 (2) 

108 dB (average) 114 dB (peak)

105 dB (average) 111 dB (peak) 

Power Handling

Average 

70 W

60 W 

Programme 

140 W

120 W 

Peak 

280 W

240 W 

Recommended Amplifier Power 

140 W @ 16 Ohms

120 W @ 16 Ohms 

Nominal Impedance 

16 Ohms 

Construction

Enclosure 

ABS / Steel

Grille 

Steel, plated and powder coat painted 

Connectors

Euroblock type removable locking connector with screw terminals with “loop through” facility

Transformer setting 

Rotary switch 

Safety Agency Ratings 

UL-1480, UL-2043, CE 

Bezel diameter 

302 mm (11.9")

260 mm (10.2") 

Overall Length 

493 mm (19.4")

423 mm (16.7") 

Net Weight 

8.2 kg (18.1 lbs)

5.8 kg (12.8 lbs) 

Shipped weight

10.4 kg (22.9 lbs)

7.6 kg (16.7 lbs) 

Transformer Taps

70 V

60 W / 30 W / 15 W / 7.5 W & low Impedance operation 

100 V

60 W / 30 W / 15 W & low Impedance operation

Summary of Contents for OCV Series

Page 1: ...Quick Start Guide OCV Series OCV 8 OCV 6 8 6 Coaxial Pendant Loudspeaker for Installation Applications V 1 0 ...

Page 2: ...cart isused usecautionwhen movingthecart apparatus combinationtoavoid injuryfromtip over 13 Unplugthisapparatusduringlightningstormsor whenunusedforlongperiodsoftime 14 Referallservicingtoqualifiedservicepersonnel Servicingisrequiredwhentheapparatushasbeen damagedinanyway suchaspowersupplycordorplug isdamaged liquidhasbeenspilledorobjectshavefallen intotheapparatus theapparatushasbeenexposed torai...

Page 3: ...oireTannoyestsoigneusementinspectéavantd êtreemballé Aprèsledéballage veuillezinspectervotreproduitpourvousassurerqu aucundommagenes estproduitpendantletransport Dans lecasimprobablededommages veuillezeninformerimmédiatementvotrerevendeuretconservervotrecarton d expédition carvotrerevendeurpeutvousdemanderdeluiretournerl unitédéfectueusepourinspection ChaqueenceinteOCVestfournieenstandardaveclesac...

Page 4: ...Loop cable around suspension point and then into the other side of the clamp Repeat 1 3 for secondary safety attachment 4 Adjust cable to the desired length 5 Release cable by depressing the clamp sockets as shown 6 Attach the hanging cable to the centre hole of the speaker bracket The safety cable can be attached to either of the secondary holes ...

Page 5: ...Quick Start Guide 19 HANGING SAFETY POINT TAP SELECTOR EUROBLOCK ...

Page 6: ...e pins 3 and 4 are in parallel where Pin 3 is negative Pin 4 is positive 4 Connect the euroblock connector then replace the rubber input seal to ensure the speaker is sealed THE SPEAKER IS SUPPLIED IN LOW IMPEDANCE MODE NEVER CONNECT THE SPEAKER TO A 70 100 VOLT AMPLIFIER WHILE IT IS SET FOR LOW IMPEDANCE 5 The OCV 6 and OCV 8 are fitted with 60 W transformers When used in distributed line systems...

Page 7: ...5 Dimensions OCV 6 Ø260 0mm 10 23 382 1 15 04 399 5 15 73 423 2 16 66 423 2 16 66 382 1 15 04 399 5 15 73 O260 0 10 23 OCV 8 445 5 17 54 492 6 19 39 465 7 18 33 302 0 11 89 492 6 19 39 445 5 17 54 465 7 18 33 O302 0 11 89 ...

Page 8: ... order HF Directivity Q 14 4 averaged 1 kHz to 6 3 kHz 11 3 averaged 1 kHz to 6 3 kHz Directivity DI 11 6 dB averaged 1 kHz to 6 3 kHz 10 5 dB averaged 1 kHz to 6 3 kHz Rated Maximum SPL 2 108 dB average 114 dB peak 105 dB average 111 dB peak Power Handling Average 70 W 60 W Programme 140 W 120 W Peak 280 W 240 W Recommended Amplifier Power 140 W 16 Ohms 120 W 16 Ohms Nominal Impedance 16 Ohms Con...

Page 9: ...zàremplacerlesfusiblesuniquementpardes modèlesexactementdemêmetailleetdemêmevaleur électrique sansaucuneexception 1 Online registrieren BitteregistrierenSie IhrneuesMusicTribe GerätdirektnachdemKaufaufder websitemusictribe com WennSieIhrenKaufmitunserem einfachenonlineFormularregistrieren könnenwirIhre Reparaturansprücheschnellerundeffizienterbearbeiten LesenSiebitteauchunsereGarantiebedingungen f...

Page 10: ... Directive 2012 19 EU Regulation 519 2012 REACH SVHC and Directive 1907 2006 EC and this passive product is not applicable to EMC Directive 2014 30 EU LV Directive 2014 35 EU Full text of EU DoC is available at https community musictribe com EU Representative Music Tribe Brands DK A S Address Ib Spang Olsens Gade 17 DK 8200 Aarhus N Denmark ...