background image

6

PERIOD

15 seconds

30 seconds

45 seconds

60 seconds

3 minutes

20 minutes

SW(1)

OFF

OFF

OFF

OFF

ON

ON

SW(2)

OFF

OFF

ON

ON

OFF

OFF

SW(3)

OFF

ON

OFF

ON

OFF

ON

PERIOD

1 seconds

10 seconds

15 seconds

30 seconds

SW(5)

OFF

OFF

ON

ON

SW(6)

OFF

ON

OFF

ON

Auto Flush Mode

SW (4)

ON - (Enable)

OFF - (Disable)

Auto Time Out Selection

Water Shut Off Delay Selection

AUTO TIME-OUT ADJUSTMENT (SWITCHES 1-3)

• 

The ChekPoint controller provides six periods to select from for shutting off  the 
water when the object is left in front of the electronic eye.  The time periods to 
select from are: 15 seconds, 30 seconds, 45 seconds, 60 seconds, 3 minutes and 
20 minutes.  The default setting is 15 seconds.

Note: The chart below indicates the switch positions required for each auto time-out mode.

WATER SHUT-OFF DELAY 

ADJUSTMENT (SWITCHES 5 & 6)

• 

The ChekPoint controller provides 

four periods to select from for 
shutting off  the water when the 
object is removed from in front of the 
electronic eye.  The time periods to 
select from are: 1 second, 10 seconds, 
15 seconds, and 30 second.   The 
default setting is 1 second.

AUTO-FLUSH (SWITCH 4)

• 

The ChekPoint controller off ers the 
option to select the Auto Flush mode 
in switch 4 position.  When enabled, 
the controller will fl ush the Chek-
Point faucet every 12 hours for 25-30 
seconds when the faucet is not used.  
Default setting from the factory is in 
the “off ” position.

General Instructions

LOW BATTERY DETECTION

• 

A red fl ashing light in the electronic eye indicates low batteries.

• 

A solid red light in the electronic eye and no water fl ow indicates the batteries 
are dead.

• 

New batteries will need to be installed.

TRANSFORMER OPTION:

IMPORTANT:  DO NOT plug the transformer into a receptacle until all wiring has been 
completed.

 This type of transformer is designed to be plugged into a 120 VAC 

wall receptacle.  The transformer is supplied with a 12 foot cable.  When used in 
conjunction with batteries, the transformer will become the primary power source.  
Plug the transformer cable into the wire lead coming from the bottom of the EC-3122 
faucet body.

Note: For the Hydro Generator (EC-HYDROGEN) power option, refer to the instruction 
manual in the EC-HYDROGEN kit ordered separately. For hard wiring and hard wire 
ganging (EC-HARDWIRE) and easy-wire (EC-EASYWIRE) ganging power options , refer to 
the instruction manual in each respective kit when ordered separately.

Summary of Contents for ChekPoint EC-3122

Page 1: ...ement shall be made within a reasonabletimeafterreceiptbyT Softhereturned product ThiswarrantydoesnotcoverItemswhich have received secondary finishing or have been altered or modified after purchase or for defects caused by physical abuse to or misuse of the product or shipment of the products Any express warranty not provided herein and any remedy for Breach of Contract which might arise is hereb...

Page 2: ...Exploded View 2 FIGURE 1 EC 3122 7 3 4 1 2 8 5 6 ...

Page 3: ...crew Wrench Kit 018160 40 2 Battery Holder 018227 45 3 2 2 GPM VR Aerator B 0199 09 4 Vandal Resistant Key 015425 45 5 Lever Handle w Screw 018230 45 6 Flex Hose w Check Valve Adapter Assembly 018232 45 7 Mounting Hardware Kit 018233 45 8 A C Transformer 5EF 0002 ...

Page 4: ... receptacle within approximately 12 from sink for plug in transformer 120 VAC 2 amp service for each plug in transformer used Installation of EC 3122 ChekPoint Faucet Refer to Figures 1 and 2 The EC 3122 ChekPoint Faucet has above deck sensor electronics and temperature control Power is supplied by four AA batteries in the top of the faucet body Another power option is an AC transformer connected ...

Page 5: ...g to the settings on SW 5 and SW 6 then the sensor range will need adjusting refer to INSTRUCTIONS FOR SETTING THE SENSOR RANGE TEMPERATURE ADJUSTMENT 1 Push the lever on the right side towards the back for hotter water 2 Pull the lever towards the front for colder water FEATURES AND SWITCH SETTINGS The EC 3122 ChekPoint controller offers settable water flow control adjustment selections These sel...

Page 6: ... FLUSH SWITCH 4 The ChekPoint controller offers the option to select the Auto Flush mode in switch 4 position When enabled the controller will flush the Chek Point faucet every 12 hours for 25 30 seconds when the faucet is not used Default setting from the factory is in the off position General Instructions LOW BATTERY DETECTION A red flashing light in the electronic eye indicates low batteries A ...

Page 7: ... be changed follow the steps below The sensing distance is adjustable from 3 4 2cm to 6 11 16 17cm 1 Shut off the water at the hot and cold supply stops 2 Place the magnet provided to the upper right side of the sensor lens and move it closer to the lens 3 Hold the magnet in place for 3 to 5 seconds The red sensor LED will come on for set up mode 4 Remove the magnet and the sensor LED will go out ...

Page 8: ...op s open if closed 2 Debris in supply hose filter washers remove clean and reinstall 3 Debris in aerator or spray head remove clean and reinstall 1 Check surroundings for factors that can contribute to the range for example bright lights highly reflective surfaces sunlight etc 2 Range too long decrease sensor range 1 Debris in solenoid valve won t close properly Contact factory Very Low Flow or S...

Page 9: ...4 Fax 864 834 3518 2441 CW Nieuwveen E mail tsbrass tsbrass com The Netherlands RELATED T S BRASS PRODUCT LINE EC 3122 4DP ChekPoint Electronic Faucet Single Hole Deck Mount with Deck Plate EC 3122 VF05 ChekPoint Electronic Faucet Single Hole Deck Mount 2 2 GPM Vandal Resistant Aerator Optional Vandal Resistant 0 5 GPM Spray Device EC 3122 HG ChekPoint Electronic Faucet Single Hole Deck Mount Hydr...