5
General Instructions
9. Connect the check valve adapters at the end of the hot and cold fl exible supply
hoses to their corresponding supply stops. Turn on the supply stops and check for
leaks.
10. To test the sensor eye on/off function and switch settings (if set), place your hand
beneath the aerator. The sensor LED will blink red once.
11. Remove your hand from the area. If the water does not stop within 2 seconds
or according to the settings on SW(5) and SW(6), then the sensor range will need
adjusting (refer to “INSTRUCTIONS FOR SETTING THE SENSOR RANGE”).
TEMPERATURE ADJUSTMENT
1. Push the lever on the right side towards the back for hotter water.
2. Pull the lever towards the front for colder water.
FEATURES AND SWITCH SETTINGS:
The EC-3122 ChekPoint controller off ers settable water fl ow control adjustment
selections. These selections are set by confi guring a bank of DIP switches in the top of
the faucet body according to the tables below. To access the DIP switches, remove the
fl at head VR star screw and the cap on top of the faucet body.
Figure 2