GENERAL SAFETY STATEMENT 

  

The following safety precautions should be reviewed to avoid injury to the user and damage to 
the  product  (and  other  products  connected  to  it).    To  avoid  potential  hazards  only  use  this 
product as specified. 

 

Only  suitably  qualified  personnel  should  use  this  equipment.    Servicing  of  this 
product should only be carried out by suitably qualified service personnel. 

 

The high voltage generated by this unit is extremely dangerous and may be fatal. 

 

This unit is designed for operation in a designated high voltage test area. 

To Avoid Fire Hazards and Personal Injury 

  Use the correct power supply lead.  Only use a suitably rated and approved power supply 

lead for the country of use. 

  Ensure that systems that the unit is to be connected to are dead. 

  Do not connect and disconnect leads whilst outputs are switched on. 

  Ensure  that  the  product  is  grounded.    To  avoid  electric  shock  it  is  essential  that  the 

grounding  conductor  is  connected  to  the  earth  ground.    An  additional  earth  terminal  is 
provided  on  the  unit  for  connection  to  a  local  earth  if  necessary.    Ensure  that  the  unit  is 
properly grounded before making any connections to inputs or outputs. 

  Output ratings must be observed to prevent fire hazards and risk of injury to the operator.  

Consult  the  product  manual  for  ratings  information  before  making  any  connections  to  the 
unit. 

  It  is  ESSENTIAL  to  consult  the  product  manual  for  rating  information  before  making  any 

connection to a terminal or terminal group marked with a warning triangle. 

  Only use fuses of a type and rating specified for this product. 

  Do not operate the unit out of its case or with any covers or panels removed. 

  Do not touch exposed connections and components when power is present. 

  Do not operate the product if any damage is suspected.  Refer the unit to qualified service 

personnel to be checked. 

  Do not operate the unit in wet or damp conditions 

  Do not operate the unit in an explosive atmosphere 

  This unit is not designed for unattended operation 

If  any  further  queries  occur  regarding  the  usage  and  maintenance  of 
the  equipment  detailed  in  this  manual,  please  refer  these  to  the 
supplier of the equipment in the first case or to: 

 

T & R Test Equipment Limited 

Summary of Contents for KV5-100 mk3

Page 1: ...igh Voltage AC Test Set Type KV5 100 mk3 DESIGNED AND MANUFACTURED BY T R Test Equipment Limited 15 16 Woodbridge Meadows Guildford Surrey GU1 1BJ United Kingdom Telephone 01483 207428 e mail sales tr...

Page 2: ...1...

Page 3: ...is provided on the unit for connection to a local earth if necessary Ensure that the unit is properly grounded before making any connections to inputs or outputs Output ratings must be observed to pr...

Page 4: ...d to both the test set and the test specimen As a minimum the current capacity of the ground leads should exceed that necessary to carry the maximum possible ground current The effect of ground potent...

Page 5: ...The following safety symbols appear in this manual CAUTION This action or procedure may be dangerous if not carried out correctly and may cause damage to the equipment or connected equipment WARNING T...

Page 6: ...tion 8 1 3 1 Variable overload 8 1 4 Metering 9 1 5 Fault Burn Facility 10 1 5 1 Fault Burning 10 1 5 2 Burn Switch 10 1 6 High Voltage Connection 10 1 7 Construction 10 2 OPERATION 11 2 1 Safety 11 2...

Page 7: ...6 3 MAINTENANCE 16 4 STANDARD ACCESSORIES 17 5 OVERALL PERFORMANCE SPECIFICATION 18 6 REVISION 19...

Page 8: ...system The interlock socket on the back panel must have a short circuit across it terminals to enable the output to be energised Note the open circuit voltage across the interlock terminals is 240Vac...

Page 9: ...ip levels are adjustable in two ranges each of 6 steps giving 2 12 and 20 120 rated current Unit Trip current ranges X1 X10 KV5 100 mk3 2 4 6 8 10 12mA 20 40 60 80 100 120mA The range change and selec...

Page 10: ...th the following metering ranges using analogue moving coil meters Unit Metering Ranges Voltage Current Low High X1 X10 KV5 100 mk3 3kV 6kV 10mA 100mA The ranges on both instruments are selected by me...

Page 11: ...lower output voltages the burn current limit reduces in proportion to the output voltage When the burn switch is in the out position the maximum current is approximately 2A for short periods of time...

Page 12: ...supply or HV unit interlock to ensure that the unit cannot be switched on unless the area is secure Refer to BS EN50191 2001 and IEEE Std 510 1983 for further details of suitable test enclosures The t...

Page 13: ...procedures must be implemented to accepted standards 2 1 2 1 Interlocks The KV5 100 mk3 series is provided with an external interlock circuit that may be used to link to interlock switches on the high...

Page 14: ...itch Selects kV meter range H Earth output lead Earth output to object under test J HV Output ON pushbutton Switches HV output on Illuminated red when output is on K Variable trip level select Selects...

Page 15: ...of Operation 2 4 1 Connections WARNING Before making any connections please ensure that you are aware of all hazards relating to the system and environment in which it is operating Ensure that the ke...

Page 16: ...p button is released and that the regulator is in the fully anti clockwise position Press the HV ON pushbutton The HV output will now energise and the red HV on indicator in the pushbutton will light...

Page 17: ...t and on the output leads Ensure that the unit is disconnected from the mains before removing any covers It is advisable to check the carbon brush on the variable transformer for signs of wear on a re...

Page 18: ...ANDARD ACCESSORIES The following items are provided with the equipment a Mains input lead b 2 keys for mains ON OFF switch c Operating Maintenance Manual d 1x F5A 1 inch fuse and 1x T4A 20mm fuse KV5...

Page 19: ...stance at 500V DC 10 megohms between mains input and frame Applied voltage test 2 0kV RMS for 1 minute between mains input and frame Accuracy of instruments kV meter 1 5 of FSD mA meter 2 5 of FSD Ins...

Page 20: ...19 6 REVISION Product Type KV5 100 mk3 series High Voltage AC Test Systems File KV5 100mk3 series manual v1 Author P Cole Issue Date 1 18 09 20 Modified By M Clancy Checked By G Bond Date 06 10 20...

Page 21: ...20 Circuit diagram A2 002174 KV5 100 mk3...

Reviews: