6

5

Recorded data and recording settings will be lost if the 
batteries run out.

It is recommended that the batteries be replaced before they run 
out.

 

Battery life depends on the measurement environment, 
communication frequency, recording interval and battery 
quality.

Approximate battery life of 1 year is a standard of battery life 
under use with a recording interval setting at 2 seconds or more 
and in no way do we guarantee a battery’s life.

Battery terminals may provide insufficient contact due to 
age or vibration.

Please be careful not to lose data due to insufficient contact.

Remove batteries from any unit that is not to be used for a 
long period of time.

Batteries left in a unit not being used for a long time may leak 
and cause a malfunction.

Use the sensor only within the measurable temperature 
range (-40 to 110

).

For extending the temperature sensor cable, use of only 1 
extension cable is advised.

Use the sensor only within the measurable temperature 
and humidity range (Temperature: 0 to 50

, Humidity: 10 

to 95%RH).

When the sensor is not used, put it in the attached plastic 
bag with a drying agent and keep it in a cool, dark place at 
5 to 25

 and 30%RH or less.

An extension cable cannot be used with the Temperature/
Humidity Sensor.

The unit may give an error in humidity value if there is a 
rapid change of temperature. However, the value will 
return to normal after the sensor temperature stabilizes.

TR-0106, Standard Temperature Sensor of TR-71S

TR-3110, Standard Humidity Sensor of TR-72S

 

  CAUTION

  CAUTION

Summary of Contents for TR-71S

Page 1: ...User s Guide Carefully read and fully understand instructions before using this unit 2002 04 16004104060...

Page 2: ...WindowsNT are registered trademarks of Microsoft Corporation USA and are binding in the USA and all other countries Company names and product names are trademarks or registered trademarks of each com...

Page 3: ...ditions with an ambient temperature of 10 to 60 and humidity of 90 RH or less Do not use or store the unit in places such as listed below In places exposed to splashing water In the direct sun light o...

Page 4: ...f time Batteries left in a unit not being used for a long time may leak and cause a malfunction Use the sensor only within the measurable temperature range 40 to 110 For extending the temperature sens...

Page 5: ...temperature The TR 72S is a data logger designed to measure display and record temperature on 1 channel and humidity on its other channel The recorded data from either unit can be downloaded to your...

Page 6: ...be used For details see page 22 Optional Sensors List TR 71S TR 72S Connect the Sensors 10 Left Side View Standard Temperature Humidity Sensor TR 3110 Standard Temperature Sensors TR 0106 Connection c...

Page 7: ...eries and Turn Power On If during recording the switch is turned OFF recording will stop and all recorded data will be stored in the main unit Power Switch ON OFF 11 Caution The replacement period for...

Page 8: ...Recording Conditions settings 13 Battery Life 1 Approximate time till BAT mark appears on the LCD display after installing a new set of batteries is as follows Recording interval of 2 sec or longer A...

Page 9: ...via Main Unit Recording can be started and interval settings made via the buttons on the main unit Only Recording Start Stop and Recording Interval can be controlled by using the main unit buttons Oth...

Page 10: ...can be set via your computer by using the software Thermo Recorder for Windows The following settings can also will be made For more details see the Thermo Recorder for Windows User s Manual or the HE...

Page 11: ...TR 71S TR 72S 2 Open Thermo Recorder for Windows on your computer and make settings such as Start Recording and other Recording Conditions For more details see Thermo Recorder for Windows User s Manu...

Page 12: ...er for Windows User s Manual or the HELP menu of the software Temperature Sensors for TR 7 Series Possible Measurement Range 40 to 110 Sensor Temperature Durability 50 to 115 Measurement Accuracy Aver...

Page 13: ...36 Sec In agitated water Approx 7 Sec TR 1320 Stainless Protection Sensor Cable Length 2m Thermal Constant Time In the Air Approx 12 Sec In agitated water Approx 2 Sec 24 Temperature and Humidity Sen...

Page 14: ...ttery Battery Life Data Back up Interface Communication Speed Dimensions Weight Temp and Humidity Durability of the Unit Standard Sensors Accessories 25 Product Specifications 1 If the unit does not w...

Page 15: ...5652 169 Sasaga Matsumoto City NAGANO 399 0033 JAPAN Phone 81 263 27 2131 Facsimile 81 263 26 4281 Homepage http www tandd co jp english E Mail overseas tandd co jp...

Reviews: