Caution:
Proper air shutter setting is
a must.
The fl ame should be just orange
and “lazy”.
It should
NEVER
be set to
create sooting on internal parts
and glass.
Caution: Burner area may be hot!
Turn off the fi replace and allow the unit to cool before proceeding.
To Adjust:
1.
Open and remove window frame and set aside. See “Window Frame Removal” section
found in the Installation and Operating Instructions manual.
2.
Remove the logs and set aside.
3.
Remove air defl ector from log grate (2 screws)
4.
Loosen the Primary Air Shutter screw.
5.
Rotate the shutter to increase or decrease the amount of primary air.
6.
Reassemble in reverse order.
The air shutter on the burner tube controls the primary combustion air to the gas burner
and is preset at the factory for natural gas fuel. Some adjustment may be necessary to
obtain desired fl ame and to eliminate carbon deposits. Evaluate fl ame appearance after
the fi replace has reached operating temperature. See Fig. #29 for proper fl ame pattern.
Open primary air shutter if the logs, glass, and fi rebox have carbon accumulation and/or
the fl ames are long, dark and stringy. The shutter may also be opened to enhance the
ember material glow and lessen the fl ame height.
Fig #29
13
TC30.NG06C 200411-16
Burner Flame Adjustment