TANDBERG Telepresence T3 Assembly Manual Download Page 11

PAGE 11/58

119078.01 TELEPRESENCE T3 SYSTEM ASSEMBLY 12.08

TANDBERG

Telepresence T3

4. 

Please make sure that the distance to the wall is constant. If necessary, mark 
the position with a piece of tape or similar.

Tape

5. 

Remove the protective film along the edges on the 

Coverplate center

 (high-

lighted in picture). Repeat for the other two coverplates.

tAblE floor struCturE

Summary of Contents for Telepresence T3

Page 1: ...PAGE 1 58 119078 01 TELEPRESENCE T3 SYSTEM ASSEMBLY 12 08 TANDBERG Telepresence T3 system assembly guide...

Page 2: ...the Client s organisation or used for any purpose whatsoever other than for evaluatory purposes by the Client All information descriptions examples and calculations contained in this document are for...

Page 3: ...g structure 29 Cable bundling in the systems 30 System cable connections left system 32 System cable connections center system 33 System cable connections right system 34 Table Top Module 35 Cable Con...

Page 4: ...ht armatures plus three fluorescent light armatures mechanically fastened together and parallel wired together Recommended positioning for the front ceiling lights is rear edge 200cm 6 6 7 10 from inn...

Page 5: ...seven 640mm spot light armatures mechanically fastened together and parallel wired together Rear edge 5cm 2 inner rear wall and 228cm 7 53 4 from the floor The front ceiling lighting consists of four...

Page 6: ...ners Trim off excess wire to approximately 8cm 3 Use the provided 4mm bolts ad plastic nuts to fasten the seven lights together in one continuous row Press in the chrome colored end plates to cap off...

Page 7: ...light armature This is only used with dimming Use a 20cm piece of the three wire lead to couple the adjacent spot fluorescentlights together There should be many extra meters of the three wire leads f...

Page 8: ...n the lid of the box with the packaging foam to ensure they are not damaged Coverplate Front right Coverplate Center Coverplate Front left Coverplate Left Coverplate End Coverplate End Coverplate Righ...

Page 9: ...om the rear white wall The distance between the white and the blue wall is 140mm 5 4 2m 13 9 to wall D oor 4 06m 13 31 2 Table Floor structure Note The system has been designed for rooms with entrance...

Page 10: ...s should be as follows 2 Shimsplate 2 Joining plate 34pcsM6 nut a 36pcsM8 nut b 62pcsM6 10 c 32pcsM4 8 d 6pcsM4 12 f 12pcsM10 30 e 6 pcs Nut M6 g Flange type 28 pcs Screw M4 12 h Pan 4 pcs Screw M4 40...

Page 11: ...4 Please make sure that the distance to the wall is constant If necessary mark the position with a piece of tape or similar Tape 5 Remove the protective film along the edges on the Coverplate center...

Page 12: ...Coverplate center to the coverplate front left using the Joining plate and the Shims plate 7 Fasten with 3 pcs of the M6 10 screw c and one nut 8 Repeat on the right side with the right cover plate Ta...

Page 13: ...19078 01 TELEPRESENCE T3 SYSTEM ASSEMBLY 12 08 TANDBERG Telepresence T3 9 When the three plates have been mounted together gently sink them onto the floor structure Do not step on the plates Table Flo...

Page 14: ...Codec to amplifier 3 Fasten by fastening 4 nuts b bottom modules 4 nut b M8 Tip The procedure outlined in this chapter suggests that you mount all three bottom modules before you mount the monitors on...

Page 15: ...PAGE 15 58 119078 01 TELEPRESENCE T3 SYSTEM ASSEMBLY 12 08 TANDBERG Telepresence T3 bottom modules...

Page 16: ...e 112980 Power Cable main in 115233 PC Connection Cable Video audio in 117083 Main Speaker Cable top of amplifier 117087 Monitor Control Cable USB DSUB 118315 External Microphone Cable Note The 117084...

Page 17: ...dio in 117083 Main Speaker Cable top of amplifier 117087 Monitor Control Cable USB DSUB 118315 External Microphone Cable 117084 Audio RCA Cable Codec to amplifier 8 Mount the right Bottom module Obser...

Page 18: ...T3 9 For the left Bottom module get the splitter brackets shown above Fasten them using 3 pcs M6 flange nuts as shown below Then place the HDMI splitter between the brackets Splitter Bracket big Spli...

Page 19: ...umn Assembly Note The Column covers and the Door covers shall not be mounted yet so please place them in a spot where they won t be damaged 1 Mount the columns using 12 nut b for each column but make...

Page 20: ...STEM ASSEMBLY 12 08 Floor cabling structure Place cable kits 1 9 in floor structure according to the figure Floor Cabling Structure shown on the previous page The numbers 1 9 match the cable kits 1 9...

Page 21: ...ec L Telepresence Control Unit Codec C Telepresence Control Unit Codec R Telepresence Control Unit Main Video Display R Telepresence Control Unit Codec R Telepresence Control Unit Module left splitter...

Page 22: ...ASSEMBLY 12 08 TANDBERG Telepresence T3 Mounting the Column tray When you have finished cabling the floor structure slide the Column tray into place as shown below The column tray is found in the box...

Page 23: ...to the center DNAM Cable 117856 to the right DNAM Space is too tight to permit a convenient cable connection after the monitor has been mounted 2 Unpack the monitor assembly and lift onto the bottom m...

Page 24: ...ce T3 3 Unscrew the top side screw of the monitor assembly on the right side of the left module both sides of the center module and the left side of the right module Note Screws must be removed before...

Page 25: ...tom module as seen from above with the door open 6 Unpack the 2 angle plates and the 8 nut plates from the box marked T3 Table Floor Structure and brackets fasten with screws through the holes on top...

Page 26: ...0 Auto 1 1080p25 0 1080p30 1 1080p50 0 1080p60 1 720p25 0 720p30 1 720p50 0 720p60 1 480p60 0 SW control 1080p25 1080p30 720p50 720p60 720p25 720p30 720p50 720p60 480p60 1 0 HDMI Camera negotiates for...

Page 27: ...nit 116805 rev 3172g A3 mm 1 5 Rev Date Prep Checked Change Telecom AS Part weight Sheet size Scale Sur Specification Material Tolerances Unit European projection Sheet 1 of 1 All materials finishes a...

Page 28: ...presented on the following pages immediately after the system cable bundling kits listings Cable Connection details system connections Tip When cabling the system we recommend that you open the Cente...

Page 29: ...PAG E 29 58 TANDBERG Telepresence T3 119078 01 TELEPRESENCE T3 SYSTEM ASSEMBLY 12 08 System cabling structure...

Page 30: ...71 Cable 9p DSUB 9p DSUB Codec R Telepresence Control Unit Codec Right Tec PC 117868 Cable 9p DSUB 9p DSUB Main Video Display R Telepresence Control Unit Display Video right Tec PC 117878 Cable RJ45 R...

Page 31: ...odec C Presentation Splitter R Codec C Codec R Cable 117854 DNAM R Codec C Codec R Codec main codec right Codec main codec right Codec main codec right Codec main codec right Codec main module right s...

Page 32: ...Telepresence T3 119078 01 TELEPRESENCE T3 SYSTEM ASSEMBLY 12 08 System cable connections left system This drawing shows the complete system cable connections for the left system Use the labels on the...

Page 33: ...lepresence T3 119078 01 TELEPRESENCE T3 SYSTEM ASSEMBLY 12 08 System cable connections center system This drawing shows the complete system cable connections for the center system Use the labels on th...

Page 34: ...elepresence T3 119078 01 TELEPRESENCE T3 SYSTEM ASSEMBLY 12 08 System cable connections right system This drawing shows the complete system cable connections for the right system Use the labels on the...

Page 35: ...plugs Table top assembly left Table top assembly center Table top assembly right Do as follows 1 Mount the Left table top to the column by fastening nuts and screws on the underside of the table top P...

Page 36: ...op 3 Lift Table top center and slide the steel profiles into the Table top left Insert the wooden plugs in the side of the center table top as for the left 4 Lift the Table top assembly center so that...

Page 37: ...3 Table Top Module 5 Drop the right table top assembly to the column and fasten 6 Fasten three screws c in each joint of the table tops 7 Tighten all screw and nuts including the remaining ones betwee...

Page 38: ...n to remove the gap between the table top plates 9 Find the Cable channels and insert them in the hole of the center table top slide them out to left and right respectively The cable channels must be...

Page 39: ...able connections This is a complete drawing of the total cabling It is available separately as a full size drawing For your convenience the connection details for each component in the systems upper p...

Page 40: ...o the right in the table leg while power cables should reside in the channels to the left This applies to both legs We recommend that you sort the cables in the opening for PC connectivity 1 2 and Tou...

Page 41: ...isplay L Tec PC Display Video Left 1 117867 Cable 9p DSUB 9p DSUB Telepresence Control Unit Main Video Display C Tec PC Display Video Main 117869 Cable 9p DSUB 9p DSUB Telepresence Control Unit Codec...

Page 42: ...17823 117903 118567 Cable HDMI HDMI Cable VGA VGA Cable VGA VGA Cable 3 5 mm plugg Single wires Cable 3 5 mm plugg Single wires Cable Power Male Female Cable Power Male Female Touch Collaboration Disp...

Page 43: ...ion Input Switch PC Connectivity L1 Presentation Input Switch PC Connectivity L2 Presentation Input Switch Display Pres Left Splitter Tec Pres Left 3 switch PC in pres Pres Left 2 switch PC in pres Pr...

Page 44: ...Left D 118555 118544 118545 118546 118547 118548 Cable Microdot Microdot Cable Microdot Microdot Cable Microdot Microdot Cable Microdot Microdot Cable Microdot Microdot Cable Microdot Microdot Mic L1...

Page 45: ...EM ASSEMBLY 12 08 Table cable connections left system When the Touch Collaboration Display has been connected make sure you set it to ON This illustration shows the cabling in the left table leg only...

Page 46: ...E 46 58 TANDBERG Telepresence T3 119078 01 TELEPRESENCE T3 SYSTEM ASSEMBLY 12 08 Table cable connections center system When the Touch Collaboration Display has been connected make sure you set it to...

Page 47: ...G E 47 58 TANDBERG Telepresence T3 119078 01 TELEPRESENCE T3 SYSTEM ASSEMBLY 12 08 Table cable connections right system When the Touch Collaboration Display has been connected make sure you set it to...

Page 48: ...moved from the switch for more convenient connection Audio cable connections Input connections Cables Nos 117820 117825 Red wire to Left on the switch Black GND to Left on the switch White yellow or b...

Page 49: ...s are found 3 Table Quick Buttons with power supply and cable kit 3 Touch Collaboration Display 22 with power supply 6 Cable Well Assemblies 2 Fasten the monitors to the monitor brackets using 8 c scr...

Page 50: ...elepresence T3 4 Connect all the cables to the monitor see the cable schematics Set the power switch to ON Note that this cannot be done after the screens have been installed 5 Sink the monitors onto...

Page 51: ...mounted screws Fasten the screws and close the lid If the lid is not flush with the table top loosen the screws and adjust the cable wells Then fasten the screws again Mounting the collaboration scree...

Page 52: ...to configure the small switches found in the back Configure according to the diagram shown on the label The left module shall have its left and right switches on the center module shall have its left...

Page 53: ...les to the micro phone and place it in on top of the bracket Make sure that the microphones are connected according to labels see page 45 and onwards for more on this The SSTB is fastened and height a...

Page 54: ...ind the TCU in the box marked T3 Telepresence kit w TCU screens and fasten the TCU to the left column using the bracket and the same screws as were just loosened The TCU is marked in green in the pict...

Page 55: ...the bracket in the right Column Switch on the Presentation input switch before mounting Make sure the DIP switch is set correctly 1 On 2 Off 3 On 4 On 5 On 6 Off 7 Off 8 Off Fasten it in the same mann...

Page 56: ...LY 12 08 TANDBERG Telepresence T3 4 screw f M4 12 15 Fasten the End cover plates to the Left and Right cover plates using 2 f screws for each plate 16 Fold the column cover around the column and faste...

Page 57: ...PAGE 57 58 119078 01 TELEPRESENCE T3 SYSTEM ASSEMBLY 12 08 TANDBERG Telepresence T3 17 Snap the Door covers into place Mounting the TCU...

Page 58: ...PAGE 58 58 119078 01 TELEPRESENCE T3 SYSTEM ASSEMBLY 12 08 TANDBERG Telepresence T3...

Reviews: