TANDBERG 8000 MXP
104
In the example above, the system will start searching for available B-channels at channel 20,
since Search is set to High and High Channel is set to 20. The system will not search for
channels below 10, since Low Channel is set to 10. Furthermore if the user tries to make an 8
channel call, the call will be established with 6 channel, since Max Channels is set to 6.
4.8.1.2.4
Line Settings
T1 Cable
Length 1
T1 Cable Length 1 specifies the distance to the CSU connected to the
E1/T1 port 1 on codec 1.
T1 Cable
Length 2
T1 Cable Length 2 specifies the cascading distance from the E1/T1 port
2 on codec 1 to the E1/T1 port 1 on codec 2. Possible values are 0-115
feet, 80-215 feet, 180-310 feet, 280-410 feet, 375-510 feet, 475-605 feet,
575-690 feet.
E1-CRC-4
E1-CRC-4 is used for most E1-PRI configurations. You can turn it off if
not supported by your E1 network equipment.
For further information see
Appendix 6
: Connecting the system to
PRI/T1.
4.8.1.2.5
Advanced ISDN-PRI Settings
NSF is a non standard facility. Your network provider may require a service selection in your
ISDN configuration. Enter the Service code here. Valid NSF service codes are from 1 to 31.
Enter 0 to disable NSF service codes.
Example:
AT&T offers several digital switched
services. These include SDN with service
code 1 and ACCUNET with service code
6.
Below is a list of common service profiles.
As these profiles may change, contact
your service provider to get the correct
profile.
Service profiles
for AT&T:
NSF Service
Disable: 0
SDN (including
GSDN): 1
Megacom 800: 2
Megacom: 3
Accunet: 6
Long Distance: 7
International 800:
8
MultiQuest: 16
Service porfiles for
Sprint:
NSF Service
Reserved: 0
Private: 1
Inwatts: 2
Outwatts:3
FX: 4
TieTrunk: 5
Service profiles for
MCI:
NSF Service
Summary of Contents for F1 D13353.02
Page 5: ...Table Of Contents v Glossary 159...
Page 6: ......
Page 18: ...TANDBERG 8000 MXP 12...
Page 162: ...TANDBERG 8000 MXP 156 6 13 Appendix 13 Declaration of Conformity...