TANDBERG 3G Gateway
Data port Command Interface User Guide
*c xConfiguration Dialplan Entry 4 Property 14 Name: "entry5_label"
*c xConfiguration Dialplan Entry 4 Property 14 Value: "Menu"
*c xConfiguration Dialplan Entry 4 Property 15 Name: "entry5_nettype"
*c xConfiguration Dialplan Entry 4 Property 15 Value: "H323"
*c xConfiguration Dialplan Entry 4 Property 16 Name: "entry5_bnumber"
*c xConfiguration Dialplan Entry 4 Property 16 Value: "90370018"
E1
E1 is the configuration of CRC4 for the ISDN PRI lines.
E1 Interface CRC4: <On/Off>
Example of
E1
feedback:
*c xConfiguration E1 Interface CRC4: Off
Ethernet
Sets LAN port speed.
NOTE! The 3G Gateway needs to reboot before the changes will apply
.
Ethernet <speed>
---
parameters:
•
speed: auto/10half/10full/100half/100full.
The speed is either set to auto or manually
from 10mb half duplex to 100mb full duplex. When set to auto the 3G Gateway will
automatically negotiate with the network and use the best available setting.
Example of
Ethernet
feedback:
*c xConfiguration Ethernet Speed: Auto
H323CallSetup
Configures for direct or via gatekeeper calling
H323CallSetup Mode: <Direct/Gatekeeper>
--
Example of H323CallSetup feedback:
*c xConfiguration H323CallSetup Mode: Direct
H323Gatekeeper
Sets gatekeeper parameters.
NOTE! H.323 services must be set before the 3G Gateway can be registered to a gatekeeper.
H323Gatekeeper Address <IPAddr>
or
H323Gatekeeper Authentication Mode <Auto/Off>
or
H323Gatekeeper Authentication ID: <S: 0, 50>
Or
H323Gatekeeper Authentication Password: <S: 0, 50>
---
sub-commands:
D1320203
14