Standby WakeupAction
Define the camera position when leaving standby mode.
Value space: <None/Preset1/Preset2/Preset3/Preset4/Preset5/Preset6/Preset7/Preset8/
Preset9/Preset10/Preset11/Preset12/Preset13/Preset14/Preset15/RestoreCameraPosition/
DefaultCameraPosition>
None:
No action.
Preset1 to Preset15:
When leaving standby the camera position will be set to the position defined by
the selected preset.
RestoreCameraPosition:
When leaving standby the camera position will be set to the position it had
before entering standby.
DefaultCameraPosition:
When leaving standby the camera position will be set to the factory default
position.
Example:
Standby
WakeupAction: RestoreCameraPosition
SystemUnit CallLogging Mode
Set the call logging mode for calls that are received or placed by the system. The call logs may then be
viewed via the GUI or using the xHistory command.
Value space: <On/Off>
On:
Enable logging.
Off:
Disable logging.
Example:
SystemUnit
CallLogging Mode: On
SystemUnit IrSensor Mode
The IR sensor LED is located in the front of the codec and flickers when an IR signal is received from the
remote control.
Value space: <On/Off/Auto>
On:
Enable the IR sensor on the codec.
Off:
Disable the IR sensor on the codec.
Auto:
Both the TANDBERG codec and camera has an IR sensor. The system will automatically disable
the IR sensor on the codec if the IR sensor at camera is enabled. Otherwise the IR sensor on the
codec will be enabled.
Example:
SystemUnit
IrSensor Mode: On
SystemUnit MenuLanguage
The setting is used to select the language for the GUI (Graphical User Interface).
Value space: <English/Norwegian/Swedish/German/French/Italian/Japanese/Russian/Spanish/Korean/
Finnish/ChineseSimplified/ChineseTraditional/PortugueseBrazilian/Turkish/Polish/Danish/Dutch>
Example:
SystemUnit
MenuLanguage: English
SystemUnit Name
Enter a System Name to define a name of the system unit. If the H.323 Alias ID is configured on the system
then this ID will be used instead of the system name. The system name will be displayed:
1) When the codec is acting as an SNMP Agent.
2) Towards a DHCP server.
Value space: <S: 0, 50>
Format:
String with a maximum of 50 characters.
Example:
SystemUnit
Name: “Meeting Room Name”
The SystemUnit settings
The Standby settings,
cont...