SerialPort BaudRate
Specify the baud rate (data transmission rate, bits per second) for the COM 1 port on the codec. The
default value is 38400.
Connection parameters for the COM port: Data bits: 8 Parity: None Stop bits: 1 Flow control: None.
Value space: <9600/19200/38400/57600/115200>
Range:
Select a baud rate from the baud rates listed (bps).
Example:
SerialPort
BaudRate: 38400
SerialPort LoginRequired
The Serial Login setting determines whether or not there should be a login when connecting to the COM 1
port at the codec.
Value space: <On/Off>
On:
Login is required when connecting to the codec through COM port.
Off:
The user can access the codec through COM port without any login.
Example:
SerialPort
LoginRequired: On
SIP Profile [1..1] Authentication [1..1] LoginName
This is the user name part of the credentials used to authenticate towards the SIP proxy.
Value space: <S: 0, 50>
Format:
String with a maximum of 50 characters.
Example:
SIP
Profile 1 Authentication 1 LoginName: “”
SIP Profile [1..1] Authentication [1..1] Password
This is the password part of the credentials used to authenticate towards the SIP proxy.
Value space: <S: 0, 50>
Format:
String with a maximum of 50 characters.
Example:
SIP
Profile 1 Authentication 1 Password:
SIP Profile [1..1] DefaultTransport
Select the transport protocol to be used over the LAN.
Value space: <UDP/TCP/TLS/Auto>
UDP:
The system will always use UDP as the default transport method.
TCP:
The system will always use TCP as the default transport method.
TLS:
The system will always use TLS as the default transport method. For TLS connections a SIP
CA-list can be uploaded using the web interface. If no such CA-list is available on the system then
anonymous Diffie Hellman will be used.
Auto:
The system will try to connect using transport protocols in the following order: TLS, TCP, UDP.
Example:
SIP
Profile 1 DefaultTransport: Auto
SIP Profile [1..1] Outbound
The client initiated connections mechanism for firewall traversal, connection reuse and redundancy. The
current version supports http://tools.ietf.org/html/draft-ietf-sip-outbound-20.
Value space: <On/Off>
On:
Set up multiple outbound connections to servers in the Proxy Address list.
Off:
Connect to the single proxy configured first in Proxy Address list.
Example:
SIP
Profile 1 Outbound: Off