background image

                                                                                                       TX7322 Addressable Sounder Base 

 

 

        Installation & Operation Manual  

04 

84.1 

970Hz 1s off / 1s on 

05 

82.3 

970Hz, 0.5s / 630Hz, 0.5s 

06 

86.2 

500Hz - 1200Hz×3, 3.5s on / 0.5s off 

07 

87.4 

2850Hz, 0.5s on / 0.5s off×3 / 1.5s off 

08 

87.4 

2850Hz 0.4s on, 0.3s off 

09 

83.2 

550Hz, 0.7s / 1000Hz, 0.33s 

10 

10 

84.3 

1500Hz -2700Hz @ 3Hz 

11 

11 

80.5 

2400Hz 

12 

12 

83.5 

500Hz -1200Hz @ 0.33Hz 

13 

13 

84.6 

2400Hz -2900Hz @ 9Hz 

14 

14 

87.8 

2400Hz -2900Hz @ 3Hz [Default] 

15 

15 

85.6 

800Hz-970Hz @ 3Hz 

16 

16 

86.5 

500Hz-1200Hz, 3.75s / 0.25s off 

17 

17 

78.9 

800Hz 1s off / 1s on [Pre-alarm] 

 

1.

 

Attach  the programming tool  to 1 and 6 Terminals of Addressable Sounder Base. Press 

“Power” to switch-on the unit.  

2.

 

Switch-on the programmer, then press button “4” to set the desired tone, as shown in figure 

14.  Write the number of the corresponding tone  and  click the button “write”.  The word 

“Success”  or  “Fail”  on the screen  means that the success  or not of the encoding mode 

setting, as shown in figure 15 and figure 16. 

3.

 

Press “Exit” key to go back Main Menu. Press “Power” to switch off the programmer.  

Address:014

Tone:014

Success

Fail

Tone:014

 

                                                                                                                               4050100446-Rev1.0-0917                                                                      

 

 

    TANDA UK  

                                                                                                                                           

Specifications are subject to change without prior notice 

      

 

Summary of Contents for TX7322

Page 1: ...TX7322 Addressable Sounder Base Installation and Operation Manual TANDA UK Technology Copyright 2017 All right reserved...

Page 2: ...Union directive 2012 19 EU WEEE directive Products marked with this symbol cannot be disposed of as unsorted municipal waste in the European Union For proper recycling return this product to your loca...

Page 3: ...on and Wiring 5 3 Addressable Sounder Base Configuration 6 3 1 Preparation 6 3 2 Parameter setting 6 3 3 Encoding Mode Setting 7 3 4 Tone Setting 8 3 5 Read Configuration 10 4 General Maintenance 10 5...

Page 4: ...tibility problem 1 2 Feature and Benefits EN54 3 compliance Built in MCU processor and digital addressing 17 tones Programmable sound output Encoding modes such as Non coding Mode Single encoding Mode...

Page 5: ...als connection diagram as shown in Figure 1 2 The bottom structure of the Addressable Sounder Base as shown in Figure 2 Install the Addressable Sounder Base on the TX3980 type base with the installati...

Page 6: ...Terminal Base Warning Disconnect the loop connection whilst connecting to the handheld programmer 3 2 Parameter setting 1 Connect the programming cable to Z1 and Z2 terminals as shown in Figure 5 Pre...

Page 7: ...s such as non coding mode single encoding mode and dual encoding mode Different encoding modes correspond to different ways of operation It can be change the encoding mode by a programming tool Non en...

Page 8: ...ding mode setting Fig 12 Success to setting Fig 13 Fail to setting Note The programming tool can still read the address of the Addressable Sounder Base in non coding mode But the controller can not ch...

Page 9: ...5s 0 25s off 17 17 78 9 800Hz 1s off 1s on Pre alarm 1 Attach the programming tool to 1 and 6 Terminals of Addressable Sounder Base Press Power to switch on the unit 2 Switch on the programmer then pr...

Page 10: ...cting the maintenance and make sure to enable the alarm warning device and confirm if up and running 6 Perform the maintenance on semi annually or depending on the site conditions 5 Troubleshooting Gu...

Page 11: ...0 7 77 4 75 5 45 71 1 69 8 75 1 72 7 75 70 6 73 9 76 3 77 8 105 71 2 70 1 74 1 75 4 135 72 0 70 4 77 5 72 3 165 70 7 70 8 74 7 76 3 Limitation of Addressable Sounder Base The alarm warning device cann...

Page 12: ...other components of the system must be repaired and or replaced immediately as they fail This product is not approved to EN54 23 Beacon Functionality and must not be used as a visual alarm device or...

Reviews: