13  CE DECLARATION OF CONFORMITY 

 
Following equipment is in complience with EMC Directive 2014/30/EU: 
 

 

 

Product: 

Thermostatic bath and circulator 

Model:   

TC16 / TC40 / TC58 

Serial code: 

Effective from 07Txxx 

Manufacturer:  Tamson Instruments bv  
 

 

van 't Hoffstraat 12 

 

 

2665 JL Bleiswijk 

 

 

The Netherlands 

 
The products are in conformity with the following specifications: 

Item 

Reference 

Description 

Test result 

RoHS Directive 

2011/65EU 

EN 61010-2-010 

Safety requirements for electrical 
equipment for measurement, control, 
and laboratory use. Particular  require-
ments for laboratory equipment for the 
heating of material 

 

Machine Directive 
2006/42/EC 

Machinery Directive, of the European 
Parliament and of the Council of 17 May 
2006/42/EC 2nd Edition June 2010 

EN 60204 

Machinery Directive and Safety 
requirements 

p, p

i

 

EN60950-1 

Low Voltage Directive 

EN61000-3-2 

Harmonics 

EN61000-3-3 

Flicker 

p

3

 

EN61000-4-2 +A1+A2 

ESD 

EN61000-4-3 +A1+A2 

Radiated immunity 

p (anechoic room) 

EN61000-4-4 

Electrical Fast Transients 

Minimum requirements pass 

EN61000-4-5+A1 

Surges 

Minimum requirements pass 

EN61000-4-6+A1 

Conducted immunity 

EN61000-4-11 +A1 

Voltage dips and Voltage variations 

EN55016-2-1 

Conducted emission 

EN55016-2-3 

Radiated emission 

p (anechoic room) 

p  

= Pass 

p

i

 

= Individually tested 

p

= Pass, condition of operating during Pst measurement: Operational with heating element 1400W. 

P

st

 and P

lt

 are not evaluated in accordance with A.5 of Annex A of EN 61000-3-3(1995) + A1(2001). 

 
not applicable were: 

Conducted discontinuous emissions (Clicks)

 

Radiated emission (OATS) 
Magnetic field immunity 

 
Entity responsible for marking this declaration : 

 

Manufacturer, Tamson Instruments bv, van 't Hoffstraat 12, Bleiswijk The Netherlands, 

 
Name   

 

 

 

R.C. van Hall  

Function 

 

 

 

Director 

Date 

 

 

 

 

Sept 18, 2017   

Version  

 

 

 

1.03 

Summary of Contents for TC16

Page 1: ...l sales tamson com Website www tamson com Tamson Instruments bv Page 1 20 tc16 40 58 man docx Rev 2 4 UK 9 21 ISO 9001 2015 NL PRO 238239125 VAT NL 80 66 34 984 B01 Bank account no NL28 INGB 0007 350...

Page 2: ...TION TO THE TC SERIES 8 6 1 GENERAL 8 6 2 PUMP 8 6 3 COOLING 8 6 4 OVER TEMPERATURE SAFETY 9 6 5 ADJUSTING THE MECHANICAL OVER TEMPERATURE PROTECTION THERMOSTAT 9 6 6 FLUID LEVEL 10 6 7 FLUID LEVEL DE...

Page 3: ...damage to the equipment or its accessories caused by incorrect operation Important When performing service maintenance or moving the apparatus always disconnect the apparatus at the main s socket Prop...

Page 4: ...el Avoid damage to the equipment or its accessories through incorrect operation Environment Panel sealing Confirms EN60529 IP65 Environment Temperature 0 tot 35 C Supply enough ventilation Humidity 5...

Page 5: ...ate included in the box as well as ASTM thermometers thermometer holders etc Please see the packing list for details concerning total contents of consignment Before filling the bath remove any remaini...

Page 6: ...ting temperature When viscosity of the bath fluid is too high at room temperature the motor fuse will be activated In such a case the bath fluid can first be heated to set point temperature When the b...

Page 7: ...370 NL95 RABO 0160100046 Chamber of commerce 27 16 95 41 Do not use demineralized or distilled water This water can lead to corrosion of the bath and moving parts The corrosion can wear out the pump b...

Page 8: ...rough a closed external system The standard pump offers a motor protection small thermal fuse which is placed on the back panel of the motor compartment This protects the motor from excessive loads Wh...

Page 9: ...l cause extreme temperature raise To prevent high temperatures the bath is fitted with a mechanical temperature switch thermostat This thermostat will switch off the bath at a preset temperature in th...

Page 10: ...too low When the bath has been installed it must be filled with an appropriate liquid When working with water the bath should be filled to 1 cm below the lid For oil the bath should be filled to not...

Page 11: ...g on If the bath has been properly filled with fluid it can be switched with the mains switch located on the front panel Choose a working temperature set point 7 2 Control Panel 1 LED Display 2 LED Ov...

Page 12: ...7 Switch for fan only for TC16 with p n 31T0671 31T0861 8 Fan only for TC16 with p n 31T0671 31T0861 7 4 Selecting parameters The front panel layout shows the following four operating keys Press short...

Page 13: ...D values can not be set manually anymore pb Changing the tuning PID parameters Proportional band value Default value is 1 range 1 100 Proportional band equals 1 proportional value Press page key to co...

Page 14: ...ir own heat capacity the use of external cooling and external connected processes circulation or working at different set point temperatures requires new settings of the PID parameters These parameter...

Page 15: ...elow provides fast finding of the PID settings and is refereed to as the method of Ziegler Nichols This procedure is only to be followed when automatic tuning is not functioning This method provides f...

Page 16: ...nt temperature to remove the fluid make sure that the hose to drain and waste container can withstand the temperature of the bath fluid When removing bath fluid do not inhale toxic vapor Always use ap...

Page 17: ...nstruments bv Problems with set point Heater LED is not burning motor is turning and temperature raises above set point Setpoint too near to room temperature Cooling of the bath is needed Temperature...

Page 18: ...error Auto reset after 2 s E6 Watchdog error Auto reset after 2 s 10 SPECIFICATION 10 1 Technical specifications overview Item Unit TC16 TC40 TC58 Ordering code 230V 50 or 60Hz 00T0671 00T0681 00T069...

Page 19: ...safe handling procedures should be provided to handlers and users Alteration of this document is strictly prohibited Except to the extent required by law republication or retransmission of this docum...

Page 20: ...6 42 EC Machinery Directive of the European Parliament and of the Council of 17 May 2006 42 EC 2nd Edition June 2010 p d EN 60204 Machinery Directive and Safety requirements p pi e EN60950 1 Low Volta...

Reviews: