FD-M
English
Page 45
Name of CVs /
Registers
CV-
no.
Reg.
no.
Input value
(Default)
Remarks and Tips
Programming
a SUSI module
7
02
9
To start the programming of
a CV of a SUSI module. The
next CV set, is valid for the
SUSI-module. The CV-no. is
entered without a leading
"9".
Example: Programming the CV#902 of the SUSI module to the value "8":
By entering the value "9" for CV#7 of the decoder, the programming mode is
started. Next the CV of the SUSI module is chosen by entering a "2" or "02"
(leaving out the leading "9") and for the CV#902 the value "8" is set. The
decoder automatically goes back to the programming of it´s own CVs. In order
to programm another CV of the SUSI module, the operation has to be repeated
completely.
Manufacturer
8
---
(62)
Read only in DCC format!
Reset
8
03
0 ... 255
Any input value restores the
settings in state of delivery.
Analogue
mode
12
06
0, 1
(0)
0 = a.c. mode
1 = d.c. mode
functions
13
41
0 ... 255
Numerical value
*
active in
(0)
F1 on
1
analogue
F2 on
2
mode
F3 on
4
(only for F1 to
F4 on
8
F8, not for F9
F5 on
16
to F12)
F6 on
32
F7 on
64
F8 on
128