Name of CVs /
Registers

CV-
no.

Reg.
no.

Input value
(Default)

Remarks and Tips

Programming
a SUSI module

7

02

9

To start the programming of
a CV of a SUSI module. The
next CV set, is valid for the
SUSI-module. The CV-no. is
entered without a leading

"9".

Example: Programming the CV#902 of the SUSI module to the value "8":
By entering the value "9" for CV#7 of the decoder, the programming mode is
started.  Next the CV of the SUSI module is chosen by entering a "2" or "02"
(leaving out the leading "9") and for the CV#902 the value "8" is set. The
decoder automatically goes back to the programming of it´s own CVs. In order
to programm another CV of the SUSI module, the operation has to be repeated
completely.

Manufacturer

8

---

(62)

Read only in DCC format!

Reset

8

03

0 ... 255

Any input value restores the
settings in state of delivery.   

Analogue
mode

12

06

0, 1
(0)

0 = a.c. mode
1 = d.c. mode

functions

13

41

0 ... 255

Numerical value

*

active in

(0)

F1 on

1

analogue

F2 on

2

mode

F3 on

4

(only for F1 to

F4 on

8

F8, not for F9

F5 on

16

to F12)

F6 on

32

F7 on

64

F8 on

128

Summary of Contents for FD-M

Page 1: ...er DCC und Motorola Format n n Function decoder DCC and Motorola Format n Anleitung n Manual D codeur de fonctions Format DCC et Motorola n Mode d emploi n Handleiding Functiedecoder DCC en Motorola f...

Page 2: ...any form or by any means electronic or mechanical including photocopying without prior permission in writing from Tams Elektronik GmbH Subject to technical modification Tout droits r serv s en particu...

Page 3: ...Required tools and materials 36 Safe and correct soldering 36 Mounting the function decoder 37 Programming the function decoder 41 Configuration variables and the registers of the FD M 44 FAQ 49 Manuf...

Page 4: ...use The function decoder is designed for mounting in a model railway locomotive or in a model railway carriage It evaluates the data sent to it by the digital central unit either in DCC or Motorola f...

Page 5: ...specified impermissibly high humidity condensation build up can cause serious injury due to electrical shock Take the following precautions to prevent this danger Never perform wiring on a powered mod...

Page 6: ...ly when soldering and remove liquid solder with a thick wet rag or wet sponge from the soldering tip Dangerous environments A working area that is too small or cramped is unsuitable and can cause acci...

Page 7: ...guarantee the electromagnetic tolerance in operation you must take the following precautions Connect the transformer only to an approved mains socket installed by an authorised electrician Make no ch...

Page 8: ...Motorola format through the registers Analogue mode The decoder can also be used in analogue model railway layouts It can be run with an A C speed control as well as with a D C speed control When put...

Page 9: ...to the function outputs freely It is possible to assign several function keys to one function output SUSI interface A SUSI module can be connected to the FD M and programmed via the decoder It is not...

Page 10: ...outputs or to the function keys Blinken Both the frequency and the keying ratio can be set E g single and alternating flash lights or strobe lights Technical specifications Data format DCC and Motorol...

Page 11: ...ning sponge a heat resistant mat a small side cutter and wire stripper a pair of tweezers tin solder 0 5 mm diameter wire diameter 0 05 mm for all connections When the total current consumption is mor...

Page 12: ...t 5 seconds after soldering To make a good soldering joint you should use a clean and unoxidised soldering tip Clean the soldering tip with a damp piece of cloth a damp sponge or a piece of silicon cl...

Page 13: ...the amplified outputs Before connecting the lighting and other accessories to the amplified outputs check if the current is below the maximum permissible value of 1 000 mA per output and the total cur...

Page 14: ...nd the accessories as follows Front lighting AUX1 Back lighting AUX2 Accessory switched via F1 AUX3 Accessory switched via F2 AUX4 Connecting accessories to the unamplified output It is possible to co...

Page 15: ...ed to be calculated for each model Ask for the max current rating when buying your LEDs You can connect several LEDs in parallel to each output In this case every LED must have a series resistor of it...

Page 16: ...m the variables CV 1 CV 3 CV 4 and CV 29 register 1 3 4 and 5 Programming with the Central Station and the Mobile Station With the Central Station or the Mobile Station of M rklin you can program the...

Page 17: ...rers setting is 3 Set all functions function f1 to f4 to off Switch on the central unit or perform a reset at the central unit Starting the programming mode Push button stop Switch off the track volta...

Page 18: ...ress at your central unit Please note that with some central units a leading 0 has to be entered 2 Operate the direction switch The lighting stops flashing 3 Set the desired value of the register by s...

Page 19: ...gned to the desired parameters Name of CVs Registers CV no Reg no Input value Default Remarks and Tips Basic address 1 01 1 255 3 Range of values in DCC Format 1 127 Tip If a value higher than 127 is...

Page 20: ...V of the SUSI module is chosen by entering a 2 or 02 leaving out the leading 9 and for the CV 902 the value 8 is set The decoder automatically goes back to the programming of it s own CVs In order to...

Page 21: ...1 6 Direction Standard 0 Reverse direction 1 14 speed levels 0 28 or 128 speed levels 2 Analoge recognition off 0 Analoge recognition on 4 Basic addresses 0 Not for MM mode Extended addresses 32 Examp...

Page 22: ...be switched with F2 X7 to be switched with F3 Example AUX2 to be switched with F5 CV 39 2 Example AUX1 and AUX3 to be switched with F6 CV 40 5 1 4 Dimming of the outputs AUX1 49 22 1 64 64 AUX2 50 23...

Page 23: ...the period of time after the maximum voltage is reduced to the dimmed value CV 49 52 Increasing the input value by 8 extends the period of time by approx 1 second Examples CV 57 60 24 Output gets the...

Page 24: ...ded to switch additional functions in Motorola format The function keys F5 to F8 are reached via the function keys F1 to F4 the function key F9 via the function key F0 FAQ Parts are getting very hot a...

Page 25: ...peed levels are turned up or the lighting cannot be switched on or off Possible cause The speed mode of the decoder and the digital control unit do not correspond Example The central is set to the mod...

Page 26: ...or two years The warranty includes the correction of faults which can be proved to be due to material failure or factory flaw We guarantee the adherence to the technical specifications of the circuit...

Page 27: ...ected to a incorrect voltage or current if damaged by other persons if damaged by faulty operation or if damaged by careless use or abuse if damaged by touching components before electrostatic dischar...

Page 28: ...amplifi e max 10 mA Onversterkte uitgang max 10 mA X1 Schienenabnehmer links Rail current collectors left Prises de courant de la voie gauches Railstroomafnemers links X2 Schienenabnehmer rechts Rail...

Page 29: ...oduls Connection of a SUSI module Connexion d un module SUSI Aansluiten van een SUSI module Fig 4 Schaltplan Circuit diagram Sch ma de principe Schakelschema 1 SUSI GND schwarz black noir zwaart 2 SUS...

Page 30: ...s Actuele informatie en tips n http www tams online de n n n n Garantie und Service Warranty and service n Garantie et service Garantie en service n n Tams Elektronik GmbH n Rupsteinstra e 10 D 30625...

Reviews: