LD-G-33 / LD-W-33
English
Page 15
!
!
!!
Next solder the connections of the field coil to the points X3 and X4 and
the connection of the motor sheild to the point RL. Should the
locomotive´s direction of motion in analogue mode not match the
direction of motion set at the speed control you have to swap the
connections to the points X3 and X4.
Connecting accessories to the outputs
Before connecting the lighting and other accessories to the outputs
check if the current is below the maximum permissible value of 500 mA
per output and the total current is below 1.500 mA (including motor
current). If lighting or other accessories with current larger than
500 mA are connected, or if the total current of the motor and the
accessories is higher than 1.500 mA the decoder will be damaged when
put into operation.
Disconnect any existing diodes in the leads to the lamps. Connect the
lamps and the accessories to the function outputs (AUX1 to AUX6) of
the decoder. The assignment of the function outputs to the function
keys will be made when programming the decoder.
If the lamp or the accessory is already connected with one side to
vehicle ground, the connection is complete. If not, connect the second
side of the lamp or the accessory to the return conductor of the
decoder (point RL).
Caution:
If you connect the accessories to the return conductor for all functions
(point RL), the accessories must be insulated. The accessories should
not make contact with metal parts of the vehicle. Possible short circuit!
The decoder will be damaged in operation.
Caution:
The return conductor for all functions (point RL) must under no
circumstances be connected to vehicle ground. Possible short circuit!
The decoder will be damaged in operation.