TP-70BS (Rev 3.0)
- 32 -
TALON TECH CO. LTD.
6-6Touch Pad Menu Tree
6-7Notice
6-7-1 Dispense Cycle
During the system or the manual dispense, the pump doesn
’
t save Recipe changes and setting
changes. At this time,
‘
Busy
’
window is shown normally.
6-7-2 Pump ID Setting
The basic ID is
‘
11
’
. If pump & touch pad is set in the first time, connect pump & touch pad as 1:1
not to double ID. ex) Pump1 : [11], Pump2 : [12], Pump3 : [13], Pump4 : [14], Pump5 : [21].
Otherwise, pump cannot be searched or although pump is searched, the setting data are
overlapped or Data Error / System Error occur. Before setting Pump ID, check that ID is valid or
not.
6-7-3 Recipe Setting
In case Recipe is not set properly, there is
“
Write Recipe Error
”
window.
But, this window is shown in only case each total dispense volume is not same as reload volume.
Other cases are applied as normal. So, be careful for
“
Dispense Time
”
setting.