![Talon TP-70BS Manual Download Page 11](http://html.mh-extra.com/html/talon/tp-70bs/tp-70bs_manual_815604011.webp)
TP-70BS (Rev 3.0)
- 7 -
TALON TECH CO. LTD.
4-1 Track Interface Signal
Recipe Select Trigger
“
0
”
Trigger Off
“
1
”
Trigger On
Recipe
Select
Start1
[1]
Start2
[2]
Start3
[3]
Remark
1
1
0
0
2
0
1
0
3
1
1
0
4
-
-
-
Not support
5
1
0
1
6
0
1
1
7
1
1
1
It is Timing Chart. On Readycondition, when Start Signal becomes active, each signal is same as the
chart. When Stop Alarm occurs, all stop even during dispensing. But, the warning alarm does
dispense. The alarm becomes clear by reset after pump clear.
Track / Auxiliary Interface
4