TP-70BS (Rev 3.0)
- 10 -
TALON TECH CO. LTD.
4-3-2Track Cable
Pin
Number
Standard Type(D-SUB 15P)
Signal Name
I/O
Description
1
N.C
Output
Option Alarm
2
COM
Output
3
N.O
Output
4
START 3
Input
Recipe Select Signal
5
START 1
Input
6
START 2
Input
7
OUT SOL
Output
8
ALARM STOP
Output
Pump Alarm(Pump Stop)
9
ALARM WARNING
Output
Pump Alarm(Pump Run)
10
HOME
Output
Pump Ready
11
END
Output
Pump Dispense End
12
IN SIOL
Output
Reload Signal
13
MC VCC
Input
MC POWER VCC (+5V~24V)
14
START VCC
Input
Dispense T5~24V)
15
MC GND
Input
MC POWER GND
Pin
Number
Track Cable(D-SUB 15P)
N2 Type
Connecting Way
Controller
Track (ACT-12)
Track(ACT-12)
1
N.C
Not Use
Alarm is only for Stop. After
disconnecting EXT High 5,
link NO/COM with EXT 2P
cable.
Dispense Trigger links Suck-
Back V/V Cable from the
system after checking (+, -).
2
COM
EXT High 5 (link after disconnect)
3
N.O
EXT High 5 (link after disconnect
)
4
START 3
Not Use
5
START 1
Dispense Trigger ( - ) 2P
6
START 2
Not Use
7
OUT SOL
Not Use
8
ALARM STOP
Not Use
9
ALARM WARNING
Not Use
10
HOME
Not Use
11
END
Not Use
12
IN SOL
Not Use
13
MC VCC
Not Use
14
START VCC
Dispense T5~24V) 2P
15
MC GND
Not Use