![Talon TP-50BS Manual Download Page 36](http://html1.mh-extra.com/html/talon/tp-50bs/tp-50bs_manual_3420571036.webp)
TP-50BS (Rev 1.0)
- 33 -
TALON TECH CO. LTD.
8-5-4 Suggested Recipe Setting Value (PR viscosity: 1,800cP)
Volume(g)
Data Input
Dispense/Time
Data Input
Reload/Time
Data Input
4.0
400
5.5
550
21
2100
4.5
450
6.0
600
21.5
2150
5.0
500
6.5
650
22
2200
5.5
550
7.0
700
22.5
2250
6.0
600
7.5
750
23
2300
6.5
650
8.0
800
23.5
2350
7.0
700
8.5
850
24
2400
Dispense time(D/T) formula : Volume(g)+1.5=D/T => ex) 5+1.5=6.5
Reload time formula : Volume(g)+16=R/T => ex) 5+17=22
※ The above data is based on 1,800cP. It is supposed to be changed upon cP.
<THE END>