User Guide
The menu
Data format (Format)
This parameter serves to define the number of data bits, the parity check for
received data bytes and the number of stop bits per data byte.
Press
Format
(3) key.
Use the
<
(2) or
>
(3) key to select the desired setting.
Setting Options: see table below
Default Setting:
8 Bit No 1 Stop
1
number of data bits
2
parity test
3
number of stop bits
7 Bit
No
2 Stop
7 Bit
Even
1 Stop
7 Bit
Odd
1 Stop
7 Bit
Even
2 Stop
7 Bit
Odd
2 Stop
7 Bit
Mark
1 Stop
7 Bit
Spc
1 Stop
7 Bit
Mark
2 Stop
7 Bit
Spc
2 Stop
8 Bit
No
1 Stop
8 Bit
No
2 Stop
8 Bit
Even
1 Stop
8 Bit
Odd
1 Stop
8 Bit
Mark
1 Stop
8 Bit
Spc
1
Sets the number of data bits: You can select 7 or 8.
2
The parity test for received data bytes can be selected.
NO
causes transmission in both directions
without parity bit. If
EVEN
or
ODD
is selected, the bytes are checked if they have even or odd parity.
The selection of
MARK
or
SPACE
causes a data byte transmission with parity bit, but without
checking the received data. Transmission data with parity bit is always marked with
1
(
MARK
) or
0
(
SPACE
).
3
Selects one or two stop bits per data byte.
Confirm the setting by pressing the
Set
key (1). Press the
Next
key (4) to access
the next group of parameters.
49
Baud Format
Online
Setup
2
1
3
4
Back
Next
8bit No
1Stop*
Online
Setup
Set
<
>
Exit
2
1
3
4
1 Stop