INSTALLATION MANUAL FOR CRYSTALLINE SOLAR PHOTOVOLTAIC MODULES
Version: A2 Effective Date: May 13, 2015
ZHONGLI TALESUN SOLAR COMPANY LIMITED
Address: No. 1 Talesun Road, Changkun Industrial Park, Shajiabang Town, Changshu, Suzhou, Jiangsu Province, 215542, P.R.China
Website:
www.talesun.com
Email:
Tel: +86 400 885 1098
8 / 19
Module Type
Module Dimension
Length*Width*Thickness
Load
A
Distance from module
edge to clamping zone
B
Clamping zone
TP672 series
1960mm*990mm*40mm
2400Pa
400mm
100mm
5400Pa
400mm
100mm
1960mm*990mm*45mm
2400Pa
400mm
100mm
5400Pa
400mm
100mm
1960mm*990mm*50mm
2400Pa
400mm
100mm
5400Pa
400mm
100mm
TP660 series
1640mm*990mm*35mm
2400Pa
250mm
100mm
5400Pa
250mm
100mm
1640mm*990mm*40mm
2400Pa
250mm
100mm
5400Pa
250mm
100mm
TP648 series
1324mm*990mm*35mm
2400Pa
200mm
100mm
5400Pa
200mm
100mm
1324mm*990mm*40mm
2400Pa
200mm
100mm
5400Pa
200mm
100mm
TP572 series
1580mm*808mm*35mm
2400Pa
200mm
150mm
5400Pa
200mm
150mm
1580mm*808mm*40mm
2400Pa
200mm
150mm
5400Pa
200mm
150mm
Use a torque wrench for installation, and the compression for each clamps is not strong to avoid potential damages to
module frames. The recommended maximum compression for each clamp is 20MPa (2900PSI).
The module mounting structure must be made of durable, corrosion-resistant and UV-resistant material. All mounting
hardware (bolt/flat washer/split washer/nut) should be stainless steel M8 size.
The minimum recommended length for each clamp is 50mm.
The modules have been designed to resist a static load of 2400Pa , and the resistance value can decrease if modules
are not mounted following the instruction above.