background image

1.3  PRODUCTION IDENTIFICATION

Each module has three labels that provide the following information:
· Nameplate: 

describes the product type; rated power, rated current, rated voltage, open circuit voltage, short 

circuit current, all as measured under standard test conditions; weight, dimension etc.; the maximum system 
voltage is 1000 volts DC is shown on the nameplate. Maximum fuse rating is also shown.

·  “QA Pass” stamp:

 module will be strictly inspected according to standard and get a QA Pass stamp on the 

backsheet.

·  2-dimensional Bar code: 

The serial number has 16 digits. There are two bar codes on each module. One is 

permanently attached to the interior of the module and is visible when viewing the front of the module, and an-
other is stuck to the rear side of the module.

·  Removing a label will make the Talesun warranty void.

2  SAFETY GUIDELINES

2.1  GENERAL SAFETY GUIDELINES

 
DANGER! Danger due to electric shock! 

All installations must be performed in compliance 

with all applicable regional and local codes, or other national or international electrical standards 
as applicable.

·  A solar module generates electricity and voltage even at low intensity of illumination. 
·  Physically disconnecting contacts in a live electrical circuit can cause arching, resulting in grave or mortal injury. 

The severity increases when several modules are connected in series. 

·  Cover the solar modules with opaque material for the entire duration of assembly. Only then is the module reli-

ably de-energized. 

·  Never disconnect plugs when under load. Be aware that even without the presence of daylight, residual charge 

may still be present in the plant. Ensure that the modules are first disconnected from the inverter prior to opening 
any contacts in the solar installation.

·  Artificially concentrated sunlight shall not be directed on the module. Solar modules produce electrical energy 

when light shines on their front surface. The DC voltage may exceed 30V. Contact with a DC voltage of 30V or 
more is potentially hazardous.

·  In the case of module or phase voltages of more than 120 V, the extra-low voltage range is left. Undertake the 

necessary protective and precautionary measures.

·  Do not insert electrically conductive parts into the plugs and junction box. Do not touch the contacts or exposed 

terminals.

·  Keep children and unauthorized persons away from the modules.
·  In case of damaged modules or operational errors of the solar array, always contact your installer or Talesun 

Technical Customer Service.

·  Do not wear metallic ornaments or metallic devices while installing or troubleshooting photovoltaic systems.

Installation manual for crystalline solar photovoltaic modules     

3

Summary of Contents for TP536M-100

Page 1: ...electing the proper supporting frame 5 3 3 Frame holes mounting 5 4 Electrical mounting 4 1 Module selection 9 4 2 Safety factor 9 4 3 General installation 9 4 4 Grounding 10 5 Commission and maintena...

Page 2: ...allation Information for operators Keep these instructions safe for the entire useful life of the solar installation Please contact your plant supplier for information concerning the formal requiremen...

Page 3: ...can cause arching resulting in grave or mortal injury The severity increases when several modules are connected in series Cover the solar modules with opaque material for the entire duration of assem...

Page 4: ...eners on the modules Use only insulated tools that are approved for work on electrical installations Do not use light concentrators e g mirrors or lenses to attempt to increase the capacity of the mod...

Page 5: ...the assembly substructure That ensures that no mechanical stress e g caused by vibrations twisting or expansion is generated on the module That ensures sufficient back ventilation of the module That...

Page 6: ...le support structures used to support PV modules at correct tilt angles should be wind and snow load rated by appropriate local and civil codes prior to installation Pole mount When installing a modul...

Page 7: ...ponsibility to ensure the clampsused to secure the module sare strong enough The modules are not subject to wind or snow loads exceeding the maximum permissible loads The module clamps which are used...

Page 8: ...edge to 1 4 width of the short frame Use a torque wrench for installation and the compression for each clamps is not strong to avoid potential damages to module frames The recommended maximum compres...

Page 9: ...of the modules and all other system components If modules are connected in series the total voltage is equal to the sum of individual voltages The recom mended max number of module N Vmax system Voc...

Page 10: ...tion The tightening torque is 1 Nm 5 COMMISSION AND MAINTENANCE 5 1 Blocking diodes and bypass diode Blocking diodes prevent current flowing from the battery to the module when no electricity is being...

Page 11: ...Technical data Module Type TP672M TP672M B TP660M TP660M B TP654M TP654M B Power Level 265 315 in increment of 5 215 265 in increment of 5 195 235 in increment of 5 Type 6inch 72cells Multi crystalli...

Page 12: ...255B 1000 IEC 255 30 2 8 44 37 5 8 81 TP660M 250 TP660M 250B 1000 IEC 250 30 1 8 31 37 3 8 78 TP660M 245 TP660M 245B 1000 IEC 245 30 0 8 17 37 2 8 69 TP660M 240 TP660M 240B 1000 IEC 240 29 8 8 06 37...

Page 13: ...IEC 250 30 3 8 25 37 3 8 69 TP660P 245 TP660P 245B 1000 IEC 245 30 1 8 14 37 1 8 65 TP660P 240 TP660P 240B 1000 IEC 240 29 7 8 08 36 9 8 62 TP660P 235 TP660P 235B 1000 IEC 235 29 5 7 97 36 8 8 59 TP66...

Page 14: ...240 47 2 5 09 58 8 5 48 TP596M 235 1000 IEC 235 46 8 5 02 58 6 5 46 TP596M 230 1000 IEC 230 46 5 4 95 58 2 5 39 TP572M 210 TP572M 210B 1000 IEC 210 38 5 53 45 8 5 83 10 TP572M 205 TP572M 205B 1000 IE...

Page 15: ...sales eu talesun com Web www talesun eu com USA Talesun Solar USA 111W Saint John Street Suite 900 San Jose CA 95113 USA Tel 1 800 276 0823 Fax 1 408 645 7111 E Mail sales USA talesun com Web www tal...

Page 16: ...www talesun eu com...

Reviews: