background image

  

 

             

Doc. No. 8030614/7–E
2005-07-15

Doc. No. 8030756/08-EN

2008-11-14

MiniMech 010

Integration Manual

D016720_01

Summary of Contents for MiniMech 010

Page 1: ...Doc No 8030614 7 E 2005 07 15 Doc No 8030756 08 EN 2008 11 14 MiniMech 010 Integration Manual D016720_01...

Page 2: ...or ATM use The manual comprises instructions for installation of MiniMech data for preparation of the site instructions for installation mechanically as well as electrically instructions for operating...

Page 3: ...upply requirements 7 Dimensions 8 MiniMech overall dimensions 8 Delivery slot dimensions 9 Note Compartment dimensions 10 Required space around the MiniMech 11 Connections 12 Power connection 12 Commu...

Page 4: ...4...

Page 5: ...5 presentation MiniMech Machine overview MiniMech Machine Controller Note Qualifier Note Outlet Note Transport Note Reject Cassette NRC 010...

Page 6: ...ilable around all sides of the MiniMech This can be achieved by mounting the MiniMech so that it can be removed from the cabinet Safety and EMC requirements The system manufacturer is responsible for...

Page 7: ...Pin assignements Pin 1 0V return Pin 2 24 V Over voltage protection The 24 VDC must not exceed 30 volts Additional On request Talaris can supply a power supply P N A008263 to run the MiniMech As an op...

Page 8: ...ns All dimensions in millimetres mm dimensions The dotted line indicates area occupied by ca bles and screw heads Dimension 122 7 is the measurement between the mounting holes at the front of the Mini...

Page 9: ...his could be achieved by using a docking device by adjusting the position of the MiniMech Note also the dimensions of the cabinet deliv ery slot and the distsance from the reference point to the botto...

Page 10: ...10 Note and Reject Cassette NRC 010 site preparation note reject cassette dimensions...

Page 11: ...ed for commissioning of the MiniMech The space in front of the MiniMech is required for removing and inserting the note compart ment The space beside the MiniMech is required for easy access to the re...

Page 12: ...SD protection Internal inter module connections and signal con nections in modules must not be touched without measures taken for ESD protection Safety Switch Connector A safety switch connector is lo...

Page 13: ...is recommended that a filter connector is used in the cabi net if the communication line is threaded out of the cabinet holding the dispensing mechanism Talaris can offer a std RS 232 communication c...

Page 14: ...y first time the machine is booted or with software com mand WD 392 0 Make sure the notes in the note tray are of adequate quality Make sure the reject compartment tray is empty In FW rev 1 3 Issue a...

Page 15: ...Con troller JP2 is for clearing the NQ data table as shown Switch off the MM010 and place or remove the jumper on JP2 Switch on the MM010 If the status of JP2 is changed from closed to open or vice ve...

Page 16: ...cassett according to the illustration Pull the reject box slightly backwards according to the illustration Lift out the note guides as shown Fitting of note guides Refit the note guides according to t...

Page 17: ...n which position to fit the note guides Push reject box back into place and tighten the six screws Note width mm Adjustment From To Position left Position right 108 111 J J 112 115 J I 116 119 I I 120...

Page 18: ...s Chassis GND The machine chassis needs to be connected to GND due to EMC levels The GND connection can be made either on one of the six fastening points on the bottom plate or with a separate cable f...

Page 19: ...19...