background image

24 independent programmable filters for each channel

Independent dual channel processing

Live and fixed filter modes

Automatic live filtering

Filter application selection(Music/Speech)

Independent level indication for each input channel

Each channel has 24 input level LEDs

2*XLR & 2*TRS balanced input and output

Button lock switch on the rear panel

Preface

Features

Dear Customer,  

Thank you for purchasing TAKSTAR FE-224N Automatic Feedback Suppressor. Please read the 

user manual carefully before operation and keep it for reference in future. If you have any 

question or suggestion, please contact our local dealer

 

13

Operation and maintenance instruction

Please read

protection ground terminal 
AC current/voltage
risky electric terminal 
This means the equipment is turned on. 
This means the equipment is turned off. 

Caution
Pay attention to the caution instruction. 
Prevent from the risk of hurt or death. 

Caution
Pay attention to the caution instruction 
to avoid product damage. The broken 
product has to be collected and 
processed separately

Caution
Before powering on, please make sure 
the power supply voltage is right for 
the machine, otherwise it leads to 
product damage or user hurt

If the 

machine will not be used for a long 
time or during the thunder and 
lightning weather, please disconnect 
with the power socket to avoid electric 
shock or fire risk. 

External connection
Please use the professional power 
cord for connection to avoid electric 
shock or death or fire risk, and ask 
qualified technician to handle the 
problem. 

Do not disassemble by yourself
High voltage inside! Electric shock risk! 
After powering on, do not disassemble 
by yourself, and ask qualified technician 
to handle the problem.
Do not repair the inner parts by yourself

Fuse
Please use the right type of specific fuse to avoid 
product damage or fire risk. It is forbidden to use 
the wrong type of fuse. Disconnect with power 
supply before replacing the fuse. 

Protection ground
Before turning on, please make sure the housing 
is connected with the protection ground to avoid 
electric shock. It is forbidden to disconnect the 
internal or external protection ground cable or 
unplug the protection ground terminal. 

Power cord and connector
Do not tread on the power cord or connector. 
Do not disconnect the protection ground connection. 
If the connector does not match with the AC socket, 
please ask the qualified technician to replace it. 
The power cord or connector can not be put under 
the heavy weight to avoid electric shock or fire risk.

Operating instruction

Please connect the machine according to the 
instruction of the manufacturer. 
Keep the machine away from rain or humid 
environment or water to avoid electric shock or 
product damage. Keep the machine away from 
heat source or fire, and do not block the ventilation 
exit to avoid fire risk.

Important safety instruction

-

Read the safety instruction. 

-

Obey the safety instruction.

-

Pay attention to all the caution content. 

-

Only use the parts specified by the manufacturer.

Cleaning
Use hair dryer or dry cloth to clean the dust. 
Do not use detergent, e.g. benzol, ethyl alcohol, etc. 
Please keep the machine clean for safety. 

Maintenance
Only ask the qualified professional technician for 
maintenance to avoid electric shock risk. 

High voltage inside! Electric shock risk!

Important Safety Instruction

12

Summary of Contents for FE-224N

Page 1: ...ite www takstar com 2 400 6828 333 0752 6383950 xs takstar com 516121 www takstar com Guangdong Takstar Electronic Co Ltd Address No 2 Fu Kang YiRd Longxi Boluo Huizhou Guangdong 516121 China Tel 86 7...

Page 2: ...1 AC...

Page 3: ...N 400 6828 333 1 2 3 3 4 5 6 8 9 10 11 22 23 25 Important Safety Instruction 12 Content 2 Preface 13 Features 13 Panel Function 14 15 Installation and Connection 16 18 User Setup 19 20 Specification 2...

Page 4: ...8 AC IEC AC AC 9 2 2 XLR 2 1 4 TRS tip ring sleeve 20dBu 0dBu 0 775Vrms 10 FE 224N 1 4 10dBu 18dBu 0dBu 10dBu 2 3 24 4 BYPASS a b 5 CLEAR SET UP a b 6 MODE a b 7...

Page 5: ...FE 224N SUB GROUP MAIN 1 TRS tip ring sleeve SUB GROUP MAIN 2 1 1 3 SUB GROUP MAIN 0dBu 10dBu FE 224N 1 TRS tip ring sleeve 2 Insert 1 1 3 4 2 1 0dBu 10dBu...

Page 6: ...0dBu 10dBu 2 SETUP LIVE 24 1 2 2 A SETUP B LIVE SETUP SETUP LIVE LIVE SETUP LIVE 1 SETUP a main mix Vocalist Sub group b CLEAR SET UP 4 c 24 1 2 2 SETUP d PFL Main Mixer e CLEAR SET UP LIVE LIVE 24 S...

Page 7: ...B A weighted 24 bit 48 kHz 106dB A weighted 0 01 1 KHz 106dB A weighted 20Hz to 20 KHz 0 5 dB 100 240V AC 50 60 Hz 15W 86dB A weighted 86dB A weighted 483x195x44mm 2 4kg 3 5kg 10 2 LIVE LIVE 24 LIVE M...

Page 8: ...elf High voltage inside Electric shock risk After powering on do not disassemble by yourself and ask qualified technician to handle the problem Do not repair the inner parts by yourself Fuse Please us...

Page 9: ...nal peak input If the clip LED lights up decrease the input signal level 3 Filter LED Each channel has 24 notch filters LEDs red to indicate the activated notch filter quantity The flashing LEDs are t...

Page 10: ...up at 0dBu and flashes occasionally at 10dBu Installation and Connection 17 FE 224N 1 Connecting with microphone channel 1 Connect the TRS tip ring sleeve stereo connector with microphone channel inpu...

Page 11: ...nly if you reset the setting LIVE mode is used to detect and eliminate the feedback noise at real time The filters unoccupied by SETUP mode will automatically work 1 Using SETUP mode confirm the sound...

Page 12: ...o SPEECH Once it detects the new feedback it will use the LIVE mode filters for the new feedback frequency If all LIVE mode filters are occupied and there is new feedback the occupied LIVE mode filter...

Page 13: ...22 23 2006 2 28 SJ T11364 2006 t ft Pb Hg Cd CrVI PBB PBDE X X X x SJ T11363 2006 B Q SJ111363 2006 E J9i 1 ff 2 3 4 5 6 4 6828 333 2...

Page 14: ...25 24...

Reviews: