background image

K11823;13/34 

- 13 - 

 

  Correlation between MGC gain setting value and MGC gain   

The  MGC setting value of this equipment is controlled 
by giving 24 to 224.   
The  correlation  between  this  setting  value  and  the 
MGC  gain  (integrated  gain  including  the  gain  of  the 
variable  gain  amplifier  and  that  of  the  fixed  gain 
amplifier) is shown in the right graph.   
 
(Note)  When the CCD element receives excessive light 

with a low gain value of the amplifier, the signals 
of  the  nonlinear  area  of  the  CCD  element  and 
the  preamplifier  are  output  at  the  high 
brightness  area  due  to  the  restriction  of  the 
dynamic  range  of  the  CCD  light  receiving 
element.   
 
In this state, unnatural image (Note below) may 
appear  in  the  neighborhood  of  the  saturating 
signal  area  of  the  image  due  to  the 
characteristic  of  the  nonlinear  area.  This 
phenomenon,  which  is  associated  with  the 
saturation characteristic of the CCD element, is 
not a failure arising from the camera.   
 
To  eliminate  this  phenomenon,  reduce  the 
amount  of  light  by  stopping  down  the  lens  and 
newly set a higher gain value. Then, the output 
signal  from  the  CCD  element  at  the  saturating 
area will be appropriately saturated into a white 
level for the output.   

 

  (Note)The above described unnatural image 

represents the following states:   

 Black and white look inverted at the saturating area. 

 The outline of the saturating area is blurred. 

 The saturating area slightly shifts upward or downward. 

 The brightness value of the saturating area does not reach 1023. 

 

 

 

(5-5)  Program page setting 

The  FC  series  cameras  incorporate  nonvolatile  memories 
and  various  operation mode  settings  and  level  settings can 
be stored in them.   
The setting items are stored in the virtual pages (hereinafter 
referred to as “program pages”) inside the camera.   
This camera has 6 program pages of “A”, “B”, “C”, “D”, “E” 
and “F” (right figure). 
 
The  camera  starts  operating  according  to  the  various 
settings stored in the relevant page when the mode switch is 
at  any  one  of  the  positions  from  “A”  to  “F”  at  the  time  of 
power-on.   
 
The camera starts operating according to the settings stored 
in the page “A” when the mode switch is at any position other 
than those from “A” to “F” at the time of power-on.   
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

Program page F 

Program pages from B to E

 

Program page A

 

[Electronic shutter operation mode] 

 Shutter system = Continuous/asynchronous 

 Type of shutter speed = High speed/ low speed 

 Electronic  shutter  table  =  Correspondence 

relation  between  shutter  switch  and  shutter 
speed 

[Other operation modes] 

 Scanning system = Normal/partial -scan 

[Level setting] 

Gain setting value = (Saved as the internal value)

Offset = (Saved as the internal value) 

Fig. 5-3 Conceptual diagram of program page

MGC GAIN CODE

M

G

C

G

A

IN

(d

B

)

6

12

18

24

0

20

40

60

80

A0

C0

E0 (hex )

32

64

96

128

160

192

224(dec)

Summary of Contents for PoCL FC1600FPL

Page 1: ...ly and manage the camera properly Keep this manual at hand and reread it whenever you are uncertain about the operation Table of Contents 1 Features 3 2 Outline 3 3 Description of each component 4 4 H...

Page 2: ...Error correction H Reset function added 2011 05 19 K11519 Adapted since Firmware Ver 1 13 7th version Error correction 2011 08 23 K11823 Description of special remarks used in this manual Note Partic...

Page 3: ...this contributes to the power saving for LED lighting and others as well as the reduction of smear The ID information set by the user for each camera can be saved and read out whenever necessary via...

Page 4: ...are shown in the following table Pin arrangement of Camera Link connector SDR 26 Connector 26 13 14 1 Mini Camera Link External view of Camera Link connector Viewed from the outside of the camera Not...

Page 5: ...PORTC7 D07 O PORTB0 PORTB4 D08 O PORTB1 PORTB5 D09 O Uppermost data PORTB2 3 6 7 O Fixed to L level CC1 Vinit2 I Asynchronous shutter trigger CC2 reserved I Reserved for future products CC3 reserved...

Page 6: ...ing the UP DOWN switch lever to the upper position or lower position 3 Return the UP DOWN switch lever to the neutral position after having heard a buzzer sounding pip pip 4 Set the mode switch to the...

Page 7: ...ive parameters of PWC and others See 6 3 How to set operation mode Recommended timing of asynchronous shutter trigger signal Vinit signal for preset shutter pulse width control For the case of preset...

Page 8: ...the lighting in any time other than this exposure time period would be wasted Since this equipment is capable of outputting strobe signal STRB even in the continuous shutter mode this output is used a...

Page 9: ...l temperature of the camera Turn on the MENU display and confirm it by the OSD over the image Temperature to be displayed in Celsius Confirm it by temperature data to be returned in response to the RS...

Page 10: ...ordance with 1 3 The signed number is obtained from 1 for the sign and 2 for the absolute value In the case of the Example 2 as above its sign is because the MSB is 1 in accordance with 1 The absolute...

Page 11: ...Partial scan The read out for each frame is conducted by the partial readout scanning The vertical width of the longitudinal picture area corresponds to 398 lines of the central portion of the image...

Page 12: ...ng The level setting is mostly divided into the following two groups Gain setting This is to set the gain amplification ratio of the preamplifier between the CCD imaging device inside the camera to A...

Page 13: ...white look inverted at the saturating area The outline of the saturating area is blurred The saturating area slightly shifts upward or downward The brightness value of the saturating area does not re...

Page 14: ...r this camera it must be set to be Pulse width control PWC ENABLED for implementing Pulse width control asynchronous shutter operation When it is set to be Pulse width control PWC DISABLED default the...

Page 15: ...om A to F Write Read When the setting of Enabled disabled for pulse width control is not set to be ENABLED the pulse width control is not effective even if the shutter switch is set to the position 9...

Page 16: ...y when the camera is turned on and that determines the operation of the camera as the current setting When the setting of a mode is changed the older one is overwritten and the new setting is temporar...

Page 17: ...ous shutter mode the repetitive trigger cyclic trigger that is generated inside the camera is automatically input Make sure to set the menu display OFF when the camera is used in the normal state onli...

Page 18: ...nged on the menu These are automatically updated when a corresponding change is made using the switches MS The current position of the mode switch is displayed SS The current position of the shutter s...

Page 19: ...the camera is turned on the data stored in the internal EEPROM nonvolatile storage are read out and copied into these areas The current operation mode of the camera is determined by the data in FR and...

Page 20: ...panel of the camera The operation modes that cannot be changed by the RS 232C commands can be changed by altering the bits of CR and FR Example 1 When a change is made from the continuous shutter mode...

Page 21: ...gger is internally generated in the cyclic trigger state when the menu is displayed therefore it is not necessary to temporarily switch to the continuous shutter operation as shown above when the menu...

Page 22: ...out are automatically saved in the program pages from A to F Carefully note that the earlier setting data that were saved by the user are all overwritten and lost Fig 6 5 Setting contents immediately...

Page 23: ...ning to power on state is received even during the periods when the camera is in the operation modes of Group 2 to D Description of commands 1 Command e Function Initialization of page memory Transmis...

Page 24: ...tter mode and shutter exposure time Transmission from host STX S A or M H or L N or P exposure time ETX Return by camera STX ACK ETX transaction completion or STX NAK ETX transaction rejection The tra...

Page 25: ...age A to H ETX Return by camera STX ACK ETX transaction completion or STX NAK ETX transaction rejection The factory default is stored in the Page H which will be used when resetting to the default set...

Page 26: ...synchronous trigger signal The internally generated trigger signal is of negative logic at 100ms 5 The minimum repetition pitch is approx 300ms Only when the trigger signal is input by this command th...

Page 27: ...on or STX NAK ETX transaction rejection The data 0 up to 15 characters of the ID code character string is read out When an ID code is not set the number of the characters to be returned is 0 20 Comman...

Page 28: ...OFFSET setting value STX WOF 64 00 ETX 27 Command RPS Function Command for reading preset Read PRESET Transmission from host STX RPS ETX Return by camera STX ACK RPS PRESET No ETX When gain and offset...

Page 29: ...erefore there is no compatibility with the conventional parallel type camera FC2000CL etc and so dedicated setting files are required Note When a channel link device is mounted directly to the capture...

Page 30: ...image 3 2 2 3 23 3 24 7 17 7 18 71 9 Partia l sca n N orma l sca n Intenal signal End of exposure Digitaloutpu t CH1 2 Unless otherwise specified the time unit of the numbers in the vertical timing ch...

Page 31: ...e becomes indefinite for the period of 1H shutter speed when a Vinit signal that is not in synchronization with the internal horizontal synchronous signal HD is input from the user side Some of the co...

Page 32: ...lues and the actual equipment should be checked for the details Vertical timing Low speed long exposure preset shutter continuous normal scan Timing of long exposure mode Internal signal internal oper...

Page 33: ...pment and remove the power cable and external connection cables When an abnormal or failure condition is detected immediately stop using this equipment cut off the power supply remove the external con...

Page 34: ...ternal Dimensions External dimensions 21 42 46 9 2 60 26 30 7 4 31 M3 Depth Depth Depth 34 40 13 5 11 11 26 Depth Right and left sides MO DE EXP U D Camera Link I O Same as top side Depth Fig 11 1 FC1...

Reviews: