11
EXTERNAL DIMENSIONS
10
SPECIFICATIONS
■
OPTION
◎
Ceiling/wall mount attachment
(variable attachment)
〔BCW-401〕
φ
4.72" (
φ
120mm)
φ
3.88" (
φ
98.5mm)
φ
3.29"
(
φ
83.5mm)
φ
0.35"
(
φ
9mm)
2.63"
(66.7mm)
5-
φ
0.17"
(5-
φ
4.2mm)
R0.59"
(R15mm)
35
°
30°
35
°
35
°
35
°
0.17"
(4.2mm)
Sensor unit
Sensor head
Variable
Release lever
Buzzer
(built in)
Locking
screw hole
Alarm LED
(Red)
Memory LED
(Yellow)
Detection window
Wiring hole
MOUNT & WIRING HOLE
Base unit
1.58" (40mm)
1.34"
(34mm)
0.41"
(10.5mm)
0.31" (8mm)
Product name
Model No.
Detection system
Detection area
Sensitivity adjustment
Power supply
Power consumption
Alarm output
Alarm memory
LED
Alarm sound
(buzzer)
Tamper output
Wiring
Ambient temp. renge
Installation
Weight
External dimensions
Appearance
Accessories
Option
FLAME SENSOR
FS-2000E
Ultraviolet rays detection
(Detected wave length 185 to 260nm)
Distance
Angle
Adjustment
range
Detection Sensitivity (STD[100%] ,L[50%])
Detection timer 4 steps (0,2 sec., 1 sec., 6sec., and 30 sec.)
10 to 30VDC (non-polarity)
Stand by : 25mA or less
Alarm : 75mA or less (alarm sound ON)
40mA or less (alarm sound OFF)
Dry contact relay Form C (alarm : open/close)
Contact action : Off delay (approx. 2sec.)
Contact capacity : 30V
・
0.3A, protective resistance 3.3 ohms
Auto-reset operation (on/off setting available)
Memory LED blinks for 3 min. then light on for 47 min.
Alarm LED (red) : light on for off delay 10sec.
Memory LED (yellow) : light on when memory
indicated, blink when power turned on
Alarm : Sounds intermittently every 0.2sec. during off delay 10sec.
Volume : 80dB or more at 3.3ft. (1m) ahead
(Silent setting is available)
Dry contact Form B (N/C)
Action : open when sensor unit is detached
Capacity : 30V
・
0.25A
Terminals
+14°F to +140°F (-10°C to +60°C) without condensation
Indoor (ceiling or wall mount)
Approx. 150g (5.25oz)
φ
4.72" (120mm)
×
H 1.58" (40mm)
ABS resin (white)
●
Tapping screw
φ
4
×
25, 2 pcs.
●
Sensor locking screw
φ
3
×
6, 1 pce.
Ceiling mount attachment (BCW-401)
33ft.(10m) [2.75"(7cm)lighter flame, in front]
Approx. 120° conically
Horizontal 25° by base unit
Vertical 30°
(
4 steps
)
by sensor head
For angle adjustment more than
horizontal 25
°
or vertical 30
°
.
alcohol
detector
elements
When detector elements are stained, spray alcohol
to the elements and remove the stain.
Do not use such chemicals as mild detergent,
thinner or benzine to clean the detector elements.
When housing is stained, clean it with a soft cloth.
Check the operation once a week.
Do'not fail to check operation
whenever a funiture in the place is
moved.
Limited Warranty :
TAKEX products are warranted to be free from defects in material and workmanship for 12 months from original date of shipment. Our warranty does not cover
damage or failure caused by natural disasters, abuse, misuse, abnormal usage, faulty installation, improper maintenance or any repairs other than those provided
by TAKEX. All implied warranties with respect to TAKEX, including implied warranties for merchantability and implied warranties for fitness, are limited in
duration to 12 months from original date of shipment. During the Warranty Period, TAKEX will repair or replace, at its sole option,free of charge, any defective
parts returned prepaid. Please provide the model number of the products, original date of shipment and nature of difficulty being experienced. There will be
charges rendered for product repairs made after our Warranty Period has expired.
Maintenance
Unit: inch (mm)