Mode selector

1 2 3 4

Detection Sensitivity

Alarm Sound

Detection timer

1

(Factory set : ON)

Detection Sensitivity

SET

L (50%)

SET

H (100%)

(Factory set : H)

2

SET

Timer

(Factory set : 1 sec.)

An alarm output occurs when the flame continues for set time of 

detection timer or longer.

Detection timer

3 4

This product alarms only by detecting a flame 

continuing for the set time of detection timer.

       (1sec., 6secs., 15secs., 30secs.)

When the flame continues further, the alarm and 

external output (when wired) are also continued  

10sec. after the flame goes out, the alarm stops and 

the sensor  goes back to armed mode.

 Installation hole

approx. 5mm

 Marking

Installation hole

Alarm (Basic action)

This product is equipped with installation holes (pitch 3.29" or 83.5mm) to make

installation easy and the sensor's  direction adjustable.

Buzzer : Sounds intermittently every 0.2sec.

LED     : Flashing every 0.2sec.

Low battery alarm will be initiated when power is 

supplied from a battery.

When low battery alarm sounds, change the battery for 

new one.  (The sensor stops its operation 2 weeks after 

the low battery alarm starts.)

Within 30sec. after the power is turned off, power on 

notice is not issued even if the power is supplied 

again.

Low battery alarm

Buzzer : Sounds intermittently every 5sec.

LED     : Flashing every 5sec.

Power on notice will sound when the power is turned on. 

When voltage is low, power on notice will not be 

heard.  Check the power supply (battery).

Power on notice

  (1) Operation

When detection sensitivity is set "L", the detection distance is 

50% shorter than when it is set "H".      

When operation is unstable on "H" setting, select "L".      

For semi-outdoor installation, "L" setting is recommended.  

  [Installation of base]

Check operation and area.

(Ref : Operation check)

When sensor unit is detached, 

wrap it in palm and slide 

release lever.

To lock sensor unit, insert 

sensor locking screw into 

locking screw hole and 

tighten it.

Set alarming sound, detection 

sensitivity and detection timer.

  (Ref : 6-(2) Function setting)

Attach the sensor unit to base 

unit.

Turn front marks of base 

unit and sensor unit to point 

in the same direction.
Insert sensor unit into base 

unit.
Push sensor unit until 

release lever is locked.

Sensor locking screw

×

×

6

OPERATION AND FUNCTION

Place the base on the site and 

mark 

× 

on 2 points 180

°

apart.

Insert the 2 pcs. of tapping 

screws (accessory) leaving 5mm 

exposed from the surface.

Adjust the sensor's direction 

by turning the base.

   (4) Tighten the screws.

● 

Installation hole

Buzzer : Sounds intermittently 3 times.

 (1)

 (2)

 (3)

(1) 

(2) 

(3) 

1 sec. 

6 sec. 

15 sec. 

30 sec. 

Detection sensitivity is selectable, H or L.

1 2 3 4

FS-1000E is equipped with 3 functions which can be 

used according to the application or environment.  

Mode setting will be done by mode selector (dip 

switch) in accordance with mode setting chart on 

the back side of sensor unit.

  (2) Mode setting

Alarm sound (buzzer)

Buzzer can be off by mode selector No.1, 

SET

ON

OFF

When the ultraviolet rays of a flame is weak (it is related to size 

of flame and distance to sensor), alarm initiation may be delayed 

beyond the set time.

The ultraviolet rays are not visible, and may be detected from 

unexpected object.

When the sensor's operation is not stable (it detects something 

but not  a flame) and its cause can not be identified, set detection 

time longer by one step and see the course.

Application and installation

For the quick detection of the flame of lighter 

/ match at no smoking zone.

Fire detection

In case of uncertain operation on the above

Fire detection in an area that may be    

  influenced by uncertain external light

When the setting is OFF Buzzer of  “Low battery alarm” and 

“powr on notic” are also off.