Setting
HoldingdowntheSETbuttonduringsettingmodereturnstheunitto
normaloperation.
Teaching errors
When teaching error occurs, the threshold value is held as before and the unit returns to normal operation.
Display Description
Solution
Err
1
The threshold value being set is beyond the limit.
・
High speed mode: 3300 or more
・
Standard/Long mode: 9700 or more
・
Decrease the light received amount.
Adjust the light source level.
Use a thinner diameter fiber cable.
Try at a longer distance.
Err 2
The threshold value being set is under the limit.
・
High speed mode: 200 or less
・
Standard mode: 270 or less
・
Long mode: 100 or less
・
Increase the light received amount.
Adjust the light source level.
Use a larger diameter fiber cable.
Try at a shorter distance.
Err 3
When the Zero offset indication is selected and
the threshold being set is under zero.
・
Increase the light received amount.
Adjust the light source level.
Use a larger diameter fiber cable.
Try at a shorter distance.
・
Select Standard or % indication.
When the Zero offset indication is selected and
trying to complete the position teaching.
・
Select Standard or % indication.