219
OPTIONS
Air Conditioner
INSPECTION AND MAINTENANCE
Inspection and maintenance interval
............................ Every 250 hours
Cleaning the Condenser
CAUTION
Cleaning the condenser with high
pressured water may damage it. Clean
the condenser gently.
If the condenser is dirty, heat will not
discharge properly. Wash dirt off the
condenser with water.
1. Open the rear cover.
2. Clean the condenser.
Inspecting and Adjusting
the Air Conditioner Belt
Inspection and maintenance interval
... After first 50 hours (New machines only)
IMPORTANT: Do not let any oil or grease
get on the belt, as it will cause the belt to
slip, shortening its service life and reducing
the air conditioner’s cooling capacity.
If the belt is slack, it will slip and vibrate,
shortening its service life and reducing the
air conditioner’s cooling capacity. The belt
should also not be too tense. Adjust the belt
tension to the standard value (approximately
8 mm or 0.3 in.).
Inspection
1. Tilt up the platform.
2. Press on the center of the belt (1) with a
finger. The belt’s tension is normal if it
bends about 8 mm (0.3 in.) when pressed
with a force of about 98N or 22 lbs.
Adjustment
If the belt’s tension is not normal, adjust it
with the adjust bolt (3).
1. Loosen the nut (4) and bolts (5).
2. Tighten the bolt (3) to increase the tension.
Loosen the bolt (3) to decrease the tension.
3. After adjusting is completed, tighten the
nut (4) and bolts (5).
Summary of Contents for TB153 FR
Page 6: ...4...
Page 8: ...6...
Page 45: ...43 MEMO...
Page 68: ...66...
Page 89: ...87 MEMO...
Page 108: ...106...
Page 180: ...178 SPECIFICATIONS Machine Dimensions...
Page 182: ...180 SPECIFICATIONS Operating Range J1K0021 D J H K C F G A E B...
Page 184: ...182 MEMO...
Page 194: ...192...
Page 225: ...223 MEMO...
Page 230: ...228...
Page 231: ...229 INDEX...