36
1-1, 2-Chome, Higashi-shinsaibashi,Chuo-ku,Osaka,Japan
Printed in Japan
TAKARA BELMONT CORPORATION
TEL : +81-6-6213-5945
FAX : +81-6-6212-3680
1E02VXA0
To ensure that this product can be used for a long period of time, conduct the inspections below.
Procedures for Daily Inspections (Continued)
□
Is the drain blocked?
□
Check that the drain is not blocked
with the drain cap, towel or
shampoo cloth.
□
Is there are any
limescale or dirt
blocking the spray
nozzle?
□
Remove the spray nozzle from the
shower head and check that there is
no limescale or dirt on it (see page
23, 24).
□
Use an item such as a toothbrush to remove any
dirt such as limescale and clean the spray nozzle.
Leaving the spray nozzle uncleaned will lead to
blockage, and water may not be output from the
shower head properly.
□
Has the tap been
turned firmly?
□
Turn the tap firmly in a clockwise
direction and check that the water
turns off properly.
□
Remove the object that is blocking the drain. If the
drain is blocked, water that is turned on
accidentally or a slight trickle of water due to an
increase in water pressure at night may cause
water to spill from the basin, leading to water
leakage.
□
Turn the tap firmly and turn the water off properly.
If the water does not turn off completely, there may
be a malfunction in the stop valves of the tap.
Close the stop valves in the water supply pipe and
hot water supply pipe (see page 25, 26), and stop
using the product immediately.
■
Items that must be inspected after closing for the day
□
Is there any water
leaking within the
basin?
□
Remove the basin maintenance
cover and check that there is no
water leaking from the internal
pipes or water taps (see page 25,
26).
□
If water is leaking from the pipes, the pipes or
gasket may be worn, degraded or damaged. Close
the stop valves in the water supply pipe and hot
water supply pipe (see page 25, 26), and stop
using the product immediately.
■
Items that must be inspected once each week
□
Does the thermostatic
control knob work
properly?
□
Turn the thermostatic control knob,
check that the water temperature is
adjusted properly and that there is
no abnormal noise.* An abnormal
gushing sound may be emitted as
water flows. (see page 17)
□
If the water temperature cannot be adjusted
properly or if there is abnormal noise, there may
be a problem with the thermostatic control within
the basin. Stop using the product immediately.
□
Can the basin be filled
with water?
□
Check that the drain cap can be used
to block the drain and that water
filling the basin does not drain.
□
When the water decreases quickly, there is a
possibility that the drain cap gasket has
deteriorated. The drain cap gasket is a
consumable part. Immediately replace it. (See
pa
ge 22.)
Inspection item
Inspection item
Inspection item
Inspection method
Inspection method
Inspection method
If the inspection results show defects
If the inspection results show defects
If the inspection results show defects