TAIYO ELECTRIC IND.CO.,LTD.
13
The sleep start timer (CT) function automati-
cally lowers the temperature of the tip after
a preset period of inactivity. This function
is exited by pressing any key on the control
panel. This function reduces power consump-
tion and helps extend soldering tip life. The
sleep function can be used with the shut
down function.
4-4 Sleep Function
CT
SST
So
ld
er
in
g
tip
te
m
pe
ra
tu
re
Set temperature
Sleep start
DIF
Operation
DIF
(Sensitivity)
Power ON
Time
(Sleep start time)
(Sleep setting temp.)
1
2
4
Setting the Sleep
Temperature (SST) Unit: °C
Key Operation
TEMP Display
Set to 200°C (392°F) before shipping.
Example
: Changing the sleep temperature
from 200°C (392°F) to 150°C (302°F).
3
Returns to the set
temperature display.
Displays
alternately
Displays
alternately
Displays
alternately
Press and hold the
key for over
3 seconds continuously.
Press the
key twice.
Press the
key, until the display
Setting completed
Press and hold the
key for over
3 seconds continuously.
changes to
150
.
While setting the sleep function, the sleep lamp will flash. The flashing of the sleep lamp will become
faster 30 seconds before entering Sleep mode. When the soldering station has entered Sleep mode,
the sleep lamp will change from flashing to continuously lit, and the display will alternate between “SLP”
and the temperature. To use sleep function manually during operation, press and hold the
▼
key for 1
second continuously. Whenever the power switch is turned ON, the soldering station will automatically
enter the Sleep mode either in 10 minutes or in twice the set sleep time (CT), whichever time is longer,
if no soldering is done. However, if soldering is started or any key is pressed on the control panel, the
soldering station will automatically revert to the set sleep start time.
The sleep function is exited when the tip is brought into contact with the tip cleaner or wet sponge.
However, this method cannot be used if the sleep temperature (SST) is set below 100
°C
because there
will be very little temperature fluctuation. Sleep mode can be exited by pressing any key on the control
panel.
Summary of Contents for Goot RX-852AS
Page 35: ...TAIYO ELECTRIC IND CO LTD 35 ...