background image

T A I T

Radio Communications

Christchurch

New Zealand

DRAWING:     T800-29-0x00  RACKFRAME

TITLE:

       RACK, DUAL 2x25W, (FYLDE

Drawn

Date

Checked

AMM

2/8/99

ABB

AMM

26/11/99

ABB

Version

1

2

Original

Drawing name changed

FRONT VIEW

REAR VIEW

Receiver

T800//

Line
level

Supply

Monitor
Volume

Monitor

Mute

Off

On

Gating

Sensitivity

Gate

Speaker Panel

T800//

RX 1

RX 2

O

F

F

O

F

F

Receiver

T800//

Line
level

Supply

Monitor
Volume

Monitor

Mute

Off

On

Gating

Sensitivity

Gate

Transmitter

Line

Sensitivity

Supply

On

Microphone

Carrier

T800//

Excellence in Radio
Communications

T800//

T800//

Power Supply

Power

On

Standby

Overload

Transmitter

Line

Sensitivity

Supply

On

Microphone

Carrier

T800//

OPTIONAL

DUPLEXER

BEHIND SPK/PROG

PANEL

OPTIONAL

DUPLEXER

OPTIONAL

BLANK

ITEMS SUPPLIED AS STANDARD

PART NUMBER

DESCRIPTION

1

T800-22-0004

RACK, FRAME ONLY, ASSEMBLED

QTY

2

T800-41-0002

DOUBLE GUIDE KIT

1

T800-44-0000

T800 PS GUIDE KIT

1

T800-15-0003

SPEAKER/PROGRAM PANEL WITH 3 POSITION SWITCH

1

T800-40-0000

FIXING KIT ONLY

1

T800-40-0001

BLANK PANEL AND FIXING KIT

1

X800-90-0001

POWER RAIL (STANDARD)

2

T800-57-0000

BACKPLANE (FYLDE)

EARTH

STUD

FUSE

TB1

OUTPUT

ONLY 13.8V

MAX

2 AMPS

FUSE

Receiver

Transmitter

T800-57-0000

Speaker

Panel

Power

Supply

Output
13.8V
25A
Max.

+

-

1
2
3
4
5

SK107

SK102

SK101

PL101

SK109

RV210

RV211

SK201

Receiver

Transmitter

T800-57-0000

SK107

SK102

SK101

PL101

SK109

RV210

RV211

SK201

REFER TO SECTION 3

OF THE

REFERENCE GUIDE

FOR

POWER RAIL OPTIONS

Summary of Contents for T800 - 22 - 0x00

Page 1: ...T800 Series II Conventional Equipment Reference Guide M800RACK 00 100...

Page 2: ...Conventional T800 Equipment Questionnaire Order Number System Rack and Function Cross Reference Chart Rack Components Weights Section 2 Rack Configurations Section 3 Rack Power Supply Options Section...

Page 3: ...T800 Series II Conventional Equipment Reference Guide Introduction...

Page 4: ...ack to produce combinations for customised solutions Tait System Solutions are open ended As well as information about the equipment there is also an order form and detailed instructions on how to fil...

Page 5: ...ation In the interests of improving the performance reliability or servicing of the equipment Tait Electronics Limited reserve the right to update the equipment or this document or both without prior...

Page 6: ...ere will be a need for Transmitter and Receiver to be in different bands this will not affect the Rackframe required ENSURE EQUIPMENT STATED IS TYPE APPROVED FOR COUNTRY OF USE PART 03 DO YOU KNOW WHA...

Page 7: ...Series II Ensure type ordered are Type Approved for Country of use PART 05 DO YOU KNOW THE FREQUENCIES This information can be helpful as sometimes the auxiliary equipment can be frequency dependant i...

Page 8: ...up procedure in the appropriate equipment manual and the frequency frequencies required are as stated in PART 05 If no frequencies are stated in Part 05 then the equipment is to be Set up on TEST fre...

Page 9: ...xx xxxx 800 880Mhz T88n xx xxxx 174 225Mhz T37n xx 400 440Mhz T85n xx xxxx 870 960Mhz T88n xx xxxx ARE REQUIRED MODULES TYPE APPROVED COUNTRY OF USE PART 03 DO YOU KNOW WHAT IS REQUIRED PER RACK Descr...

Page 10: ...XILLIARY EQUIPMENT Description OPTION REQUIRED Qty Part Number For Freq Mhz Power Monitor Kit Automatic Changeover Unit Installation Kit PART 07 ANCILLIARY EQUIPMENT Description Qty Part Number Cabine...

Page 11: ...Duration Secs Number of Channels Audio Response Single Pre emphasised Freq MHz Flat Multiple Special Modifications Pattern Required No Yes Line Level dBm Refer to Part 08 PART 12 RECEIVER PARAMETERS S...

Page 12: ...T800temp V11 doc Issued 09 Sept 1999 Page 4 of 4 SYSTEM BLOCK DIAGRAM OPTIONAL...

Page 13: ...ons Each Rack is fully wired and set up for AC or DC power supply options Refer to Section 3 A Speaker Programming Port Panel and all required Blank Panels and are fitted as standard to each rack as r...

Page 14: ...0XX T818 01 0000 TA087 01 0000 TA387 01 TA136 02 0000 0 1 2 No Duplexer Fitted 50 Watt Duplexer Fitted Coaxial Relay This item code is always set to 0 for Slimline configurations If Duplexer item code...

Page 15: ...0x00 2 2 2 2 2 2 2 2 2 2 2 2 T800 22 0x06 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 T800 22 0x10 2 2 2 2 2 2 2 2 2 2 2 2 T800 22 0x11 2 2 2 2 2 2 2 2 2 2 T800 22 0x12 2 2 2 2 2 2 2 2 2 2 2 2 2 2 T800 22 0x14 2...

Page 16: ...t 25W Transmit Receive only Dual system Single system Module Function 2 2 2 2 2 2 2 2 2 2 2 2 2 2 T800 25 0000 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 T800 25 0001 2 2 2 2 2 2 2 2 2 2 2 2 2 2 T800 25 0002 2 2...

Page 17: ...05 T8n7 Exciter 2 05 50W Power Amplifier 3 20 100W Power Amplifier 3 55 T80n Power Supply 2 30 Circuit breaker 0 50 DC Converter Module 0 90 TA136 Alarm Unit 0 85 T818 Monitor 0 95 TA807 Channel Panel...

Page 18: ......

Page 19: ...T800 Series II Conventional Equipment Reference Guide Rack Configuration...

Page 20: ...ttery Configuration Options Duplexer Coaxial Relay Fans single or double Interfaces to Changeover Module TA703 00 xxxx using TA703 11 0010 installation kit microphone DC converter Mechanical Character...

Page 21: ...nications T800 Excellence in Radio Communications T800 Speaker Panel T800 OPTIONAL TRANSMITTER OPTIONAL BLANK OPTIONAL DUPLEXER FAN OPTIONAL OPTIONAL BLANK ITEMS SUPPLIED AS STANDARD PART NUMBER DESCR...

Page 22: ...n Options Duplexer Coaxial Relay Fans single or double Interfaces to Changeover Module TA703 00 xxxx using TA703 11 0010 installation kit Microphone DC converter Mechanical Characteristics 5 Rack Unit...

Page 23: ...s T800 Excellence in Radio Communications T800 Excellence in Radio Communications T800 FRONT VIEW REAR VIEW ITEMS SUPPLIED AS STANDARD PART NUMBER DESCRIPTION 1 T800 22 0004 RACK FRAME ONLY ASSEMBLED...

Page 24: ...only x 2 AC and External DC x 3 AC and Battery x 4 External DC and Battery x 5 AC and External DC and Battery Configuration Options Channel Panel Duplexer Coaxial Relay Fans single or double Interfac...

Page 25: ...cellence in Radio Communications T800 Speaker Panel T800 OPTIONAL TRANSMITTER OPTIONAL BLANK OPTIONAL DUPLEXER OPTIONAL CHANNEL PANEL FAN OPTIONAL OPTIONAL BLANK 1 X800 90 0000 POWER RAIL STANDARD SEC...

Page 26: ...nterface Power Supply Options x 0 AC only x 1 External DC only x 2 AC and External DC x 3 AC and Battery x 4 External DC and Battery x 5 AC and External DC and Battery Configuration Options Channel Pa...

Page 27: ...e Monitor Mute Off On Gating Sensitivity Gate Receiver T800 Line level Supply Monitor Volume Monitor Mute Off On Gating Sensitivity Gate OPTIONAL CHANNEL PANEL OPTIONAL or BLANK Receiver Speaker Selec...

Page 28: ...ply Options x 0 AC only x 1 External DC only x 2 AC and External DC x 3 AC and Battery x 4 External DC and Battery x 5 AC and External DC and Battery Configuration Options Channel Panel Fans single or...

Page 29: ...me Monitor Mute Off On Gating Sensitivity Gate OPTIONAL CHANNEL PANEL OPTIONAL or BLANK Excellence in Radio Communications T800 Speaker Panel T800 Receiver Speaker Select 1 6 2 5 3 4 1 X800 90 0000 PO...

Page 30: ...d External DC x 3 AC and Battery x 4 External DC and Battery Not Available see T800 22 0x16 x 5 AC and External DC and Battery Configuration Options Coaxial Relay Fans single or double Interfaces to C...

Page 31: ...rrier T800 T800 Power Low forward power High reverse power Supply Power Amplifier FAN OPTIONAL FAN OPTIONAL 1 X800 93 0002 POWER RAIL STANDARD SECTION 4 REFERENCE SECTION 4 SECTION 4 SECTION 4 SECTION...

Page 32: ...ery x 4 External DC and Battery Not Available see T800 22 0x17 x 5 AC and External DC and Battery Configuration Options Channel Panel Individual Speaker Programming panels Duplexer Coaxial Relay Fans...

Page 33: ...y Gate Transmitter Line Sensitivity Supply On Microphone Carrier T800 Speaker Panel T800 RX 1 RX 2 O F F O F F Excellence in Radio Communications T800 OPTIONAL SPEAKER T800 15 0000 OPTIONAL DUPLEXER A...

Page 34: ...x 1 External DC only x 2 AC and External DC x 3 AC and Battery x 4 External DC and Battery x 5 AC and External DC and Battery Configuration Options Coaxial Relay Fans single or double Interfaces to C...

Page 35: ...ute Off On Gating Sensitivity Gate Transmitter Line Sensitivity Supply On Microphone Carrier T800 Speaker Panel T800 RX 1 RX 2 O F F O F F 1 X800 22 0015 POWER RAIL STANDARD SECTION 4 REFERENCE SECTIO...

Page 36: ...ernal DC Not Available x 3 AC and Battery Not Available x 4 External DC and Battery x 5 AC and External DC and Battery Not Available Configuration Options Coaxial Relay Fans single or double Interface...

Page 37: ...High reverse power Supply Power Amplifier Speaker Panel T800 RX 1 RX 2 O F F O F F FAN OPTIONAL FAN OPTIONAL 1 X800 91 0002 POWER RAIL STANDARD SECTION 4 REFERENCE SECTION 4 SECTION 4 SECTION 8 SECTI...

Page 38: ...800 22 0x14 x 3 AC and Battery Not Available see T800 22 0x14 x 4 External DC and Battery x 5 AC and External DC and Battery Not Available see T800 22 0x14 Configuration Options Channel Panel Duplexer...

Page 39: ...n Gating Sensitivity Gate Transmitter Line Sensitivity Supply On Microphone Carrier T800 Excellence in Radio Communications T800 RX 1 RX 2 O F F O F F OPTIONAL DUPLEXER and or CHANNEL PANEL 1 X800 91...

Page 40: ...ery Not Available x 5 AC and External DC and Battery Configuration Options Channel Panel Duplexer Coaxial Relay Fans single or double Interfaces to Changeover Module TA703 00 xxxx using TA703 11 0011...

Page 41: ...0 Power Supply Power On Standby Overload OPTIONAL TRANSMITTER OPTIONAL BLANK PANEL FAN OPTIONAL 1 X800 90 0000 POWER RAIL STANDARD SECTION 4 REFERENCE SECTION 4 SECTION 4 SECTION 4 SECTION 8 SECTION 3...

Page 42: ...ternal DC and Battery x 5 AC and External DC and Battery Not Available Configuration Options Channel Panel Duplexer Coaxial Relay Fans single or double Interfaces to Changeover Module TA703 00 xxxx us...

Page 43: ...rrier T800 T800 Circuit Breaker On 1 0 Off Supply 12V 1 X800 22 0121 POWER RAIL STANDARD SECTION 5 SECTION 3 ITEMS SUPPLIED AS STANDARD PART NUMBER DESCRIPTION 1 T800 22 0004 RACK FRAME ONLY ASSEMBLED...

Page 44: ...ternal DC and Battery x 5 AC and External DC and Battery Not Available Configuration Options Channel Panel Duplexer Coaxial Relay Fans single or double Interfaces to Changeover Module TA703 00 xxxx us...

Page 45: ...ier T800 T800 Power Low forward power High reverse power Supply Power Amplifier 1 SECTION 4 REFERENCE SECTION 4 SECTION 4 SECTION 4 SECTION 8 SECTION 6 SECTION 3 SECTION 4 SECTION 8 SECTION 8 SECTION...

Page 46: ...n Options Channel Panel Duplexer Coaxial Relay Fans single or double Interfaces to Changeover Module TA703 00 xxxx using TA703 11 0011 installation kit microphone DC converter Mechanical Characteristi...

Page 47: ...LANK OPTIONAL DUPLEXER OPTIONAL CH PNL FAN OPTIONAL OPTIONAL TRANSMITTER OPTIONAL BLANK 1 X800 93 0000 POWER RAIL STANDARD SECTION 4 REFERENCE SECTION 4 SECTION 4 SECTION 4 SECTION 8 SECTION 5 SECTION...

Page 48: ...on Options Channel Panel Duplexer Coaxial Relay Fans single or double Interfaces to Changeover Module TA703 00 xxxx using TA703 11 0011 installation kit microphone DC converter Mechanical Characterist...

Page 49: ...PTIONAL OPTIONAL TRANSMITTER OPTIONAL BLANK 1 X800 93 0000 POWER RAIL STANDARD SECTION 4 REFERENCE SECTION 4 SECTION 4 SECTION 4 SECTION 8 SECTION 5 SECTION 3 SECTION 4 SECTION 8 1 T800 50 0000 BACKPL...

Page 50: ...ee T800 23 0x01 x 1 External DC only x 2 AC and External DC Not Available x 3 AC and Battery Not Available x 4 External DC and Battery x 5 AC and External DC and Battery Not Available Configuration Op...

Page 51: ...r Transmitter TB Receiver Line Level Supply Monitor Volume Monitor Gating Sensitivity Gate On Off T800 Transmitter Line Sensitivity Supply Exciter Out On Microphone Carrier T800II Slimline ITEMS SUPPL...

Page 52: ...1 External DC only Not Available see T800 23 0x00 x 2 AC and External DC x 3 AC and Battery x 4 External DC and Battery Not Available x 5 AC and External DC and Battery Configuration Options Coaxial R...

Page 53: ...Power Supply TB Receiver Line Level Supply Monitor Volume Monitor Gating Sensitivity Gate On Off T800 Transmitter Line Sensitivity Supply Exciter Out On Microphone Carrier T800II Slimline ITEMS SUPPL...

Page 54: ...interface Battery Isolation Switch Configuration Options Channel Panel Duplexer Coaxial Relay Antenna Mechanical Characteristics Portable case to house up to 4 modules Top Mounting Duplexer Tray Size...

Page 55: ...T800 15 0000 SPKR PROG PNL or TA087 01 0000 100 CHANNEL CHANNEL PANEL or TA387 01 0000 10 CHANNEL CHANNEL PANEL EXTERNAL DC BATTERY OPERATION TALK THROUGH BASE STATION REPEATER FUSE 10A T800 50 0001 D...

Page 56: ...fuse Backplane interface Battery Isolation Switch Talk Through Switch Configuration Options Channel Panel Duplexer Coaxial Relay Antenna Mechanical Characteristics Portable case to house up to 4 modu...

Page 57: ...100 CHANNEL CHANNEL PANEL or TA387 01 0000 10 CHANNEL CHANNEL PANEL T800 Power Supply Power On Standby Overload EXTERNAL DC BATTERY OPERATION TALK THROUGH BASE STATION REPEATER Output 13 8V 25A Max 1...

Page 58: ...ce Battery Isolation Switch Talk Through Switch Configuration Options Channel Panel Duplexer Coaxial Relay Antenna Mechanical Characteristics Portable case to house up to 4 modules Top Mounting Duplex...

Page 59: ...BATTERY OPERATION TALK THROUGH BASE STATION REPEATER Exciter Line Sensitivity Supply On Microphone Carrier T800 T800 Power Low forward power High reverse power Supply Power Amplifier T800 15 0000 SPKR...

Page 60: ...2 AC and External DC x 3 AC and Battery x 4 External DC and Battery x 5 AC and External DC and Battery Configuration Options Coaxial Relay Fans single or double Interfaces to Changeover Module TA703 0...

Page 61: ...wer Aux 0 Fwd Power Aux 1 Low Battery Aux 2 Line Fail Aux 3 Programming Port Clear Alarms Test 3 sec Remote Alarm T800 Talk Through Base Station Monitor On Off Monitor Volume Mode Toggle Rev Power Aux...

Page 62: ...ternal DC x 3 AC and Battery x 4 External DC and Battery x 5 AC and External DC and Battery Configuration Options Duplexer Coaxial Relay Fans single or double Interfaces to Changeover Module TA703 00...

Page 63: ...DUPLEXER Remote Alarm T800 Talk Through Base Station Monitor On Off Monitor Volume Mode Toggle Rev Power Aux 0 Fwd Power Aux 1 Low Battery Aux 2 Line Fail Aux 3 Programming Port Clear Alarms Test 3 s...

Page 64: ...DC only x 2 AC and External DC x 3 AC and Battery x 4 External DC and Battery x 5 AC and External DC and Battery Configuration Options Duplexer Coaxial Relay Fans single or double Interfaces to Change...

Page 65: ...forward power High reverse power Supply Power Amplifier OPTIONAL TRANSMITTER OPTIONAL BLANK OPTIONAL BLANK OPTIONAL BLANK Excellence in Radio Communications T800 OPTIONAL TRANSMITTER OPTIONAL BLANK 1...

Page 66: ...ons x 0 AC only x 1 External DC only x 2 AC and External DC x 3 AC and Battery x 4 External DC and Battery x 5 AC and External DC and Battery Configuration Options Fans single or double microphone DC...

Page 67: ...sitivity Supply On Microphone Carrier T800 OPTIONAL DUPLEXER BEHIND SPK PROG PANEL OPTIONAL DUPLEXER OPTIONAL BLANK ITEMS SUPPLIED AS STANDARD PART NUMBER DESCRIPTION 1 T800 22 0004 RACK FRAME ONLY AS...

Page 68: ...C only x 1 External DC only x 2 AC and External DC x 3 AC and Battery x 4 External DC and Battery x 5 AC and External DC and Battery Configuration Options Fans single or double microphone DC converter...

Page 69: ...upply Power Amplifier Excellence in Radio Communications T800 Speaker Panel T800 OPTIONAL DUPLEXER OPTIONAL BLANK ITEMS SUPPLIED AS STANDARD PART NUMBER DESCRIPTION 1 T800 22 0004 RACK FRAME ONLY ASSE...

Page 70: ...e x 1 External DC only x 2 AC and External DC Not Available x 3 AC and Battery Not Available x 4 External DC and Battery x 5 AC and External DC and Battery Not Available Configuration Options Fans sin...

Page 71: ...ume Monitor Mute Off On Gating Sensitivity Gate Exciter Line Sensitivity Supply On Microphone Carrier T800 1 X800 91 0002 POWER RAIL STANDARD REFERENCE SECTION 4 SECTION 4 SECTION 4 SECTION 8 SECTION...

Page 72: ...T800 Series II Conventional Equipment Reference Guide Rack Power Supply Options...

Page 73: ...000RAIL 100W AC X DC BATfor1supply X800 90 0001RAIL 2x25W ACfor2supply X800 91 0001RAIL 2x25W AC X DCfor2supply X800 92 0001RAIL 2x25W ACfor2supply X800 93 0001RAIL 2x25W AC BATfor2supply X800 94 0001...

Page 74: ...TTERY BACK UP FUSE TB1 OPTIONAL POSITION OUTPUT ONLY 13 8V MAX 2 AMPS DIODE PACK EARTH STUD DC INPUT FUSE TB1 OUTPUT ONLY 13 8V MAX 2 AMPS EARTH STUD DC INPUT FUSE TB1 OUTPUT ONLY 13 8V MAX 2 AMPS DIO...

Reviews: