![TAILY AUTOMATION CNC-210A User Manual Download Page 18](http://html1.mh-extra.com/html/taily-automation/cnc-210a/cnc-210a_user-manual_3268300018.webp)
CNC-210A Series H6681 User manual
Page
18
of
20
έᚊཝҋજ̼ѣࢨ̳Φ
TAILY AUTOMATION CO.,LTD.
10.3. Error message
When a fault occurs during operation, the DATA DISPLAY shows error massage, stop winding
and then RESET go back to the READY mode.
Err-0
:
The parameters or data in memory are fault.
Err-1
:
The
『
SHIFT
』
value sets exceed the Travel Limit.
Err-2
:
During winding, the guiding traverse to exceed the Travel Limit.
Err-3
:
During winding, the guiding traverses
reach to the Home sensor.
Err-5
:
RS-485 communication error.
Err-p
:
Password error, key in 4 numbers password before edit.
10.4. To abort seeks the original position
At boot and reset procedures, if because of unknown reason however engender the winding
shaft and guiding traverse can't find out the original position and make the controller can't get into
ready mode, can press
key to abort seeks the original position, make controller get into ready
mode.
10.5. Troubleshooting
This section provides information to guide the user in understanding different fault condition and
their general troubleshooting procedures, and with their possible solutions.
Do not connect or disconnect wires and connectors while power is applied to the controller.
Make sure that the leads and connectors are connected correctly, before doing the
troubleshooting procedures.
Do not remove welded parts on the PC board without appropriate tools.
NO
Fault Description
Correctives Action
1
Power ON, but the display
shows nothing.
Check AC power input.
Check the LED lamp on TLP-503D power supply, if not lit
replace TLP-503D
Replace 210A-CPU.
2
Power ON, but the display
shows confusion massage,
Replace 210A-CPU.
3
Power ON, but winding
spindle didn’t rotate, or
cannot stop rotation, And
controller cannot get into
ready mode.
Press
to make the controller get into READY mode.
Check the winding parameter
『
L.S.
』
setting value of START
STEP
。
Replace turns counter CNTB-03B.
Replace 210A-CPU.
4
Power ON, but guiding
traverse didn’t move or
cannot stop moving, And
controller cannot get into
ready mode.
Press
to make the controller get into READY mode.
Replace HOME SENSOR.
Replace 210A-DVR.
Replace 210A-CPU.