4
Step 1S – Press NEXT and DOWN simultaneously for 3 seconds and release.
Step 2S – Choose SOFTENING using UP or DOWN. Press NEXT to go to Step 3S. Press
REGEN to exit Softener System Setup.
Step 3S – Select the time for the first cycle (which in this example is BACKWASH) using UP
or DOWN. Press NEXT to go to Step 4S. Press REGEN to return to previous step.
Step 4S – Select the time for the second cycle (which in this example is DRAW) using UP or
DOWN. Press NEXT to go to Step 5S. Press REGEN to return to previous step.
Step 5S – Select the time for the third cycle (which in this example is RINSE) using UP or
DOWN. Press NEXT to go to Step 6S. Press REGEN to return to previous step.
Step 6S – Select the LBS for the fourth cycle (which in this example is FILL) using UP or
DOWN. Press NEXT to go to Step 7S. Press REGEN to return to previous step.
Step 7S – Set Grains Capacity using UP or DOWN. The ion exchange capacity is in grains of
hardness as calcium carbonate for the system based on the pounds of salt that will be used.
Calculate the pounds of salt using the fill time previously selected. Grains capacity is affected
by the fill time. The grains capacity for the selected fill time should be confirmed by testing.
The capacity and hardness levels entered are used to automatically calculate reserve
capacity when capacity is set to AUTO. Press NEXT to go to Step 8S. Press REGEN to
return to previous step.
Step 8S – Set Volume Capacity using UP or DOWN. If valve is set to:
“AUTO” capacity will be automatically calculated and reserve capacity will be
automatically estimated;
“OFF” regeneration will be based solely on the day override set (see Installer Display
Setting Step 3I); or
A number, regeneration initiation will be based off the value specified.
If “OFF” or a number is used, hardness display will not be allowed to be set in Installer
Display Settings Step 2I.
If “OFF” is selected. Regeneration Time is automatically “Delayed”, so Step 9S will not
appear.
See Setting Options Table for more detail. Press NEXT to go to Step 9S. Press REGEN to
return to previous step.