12
Active Balance - Cool Blue Balancer
Configuration 2 - ‘Single Battery Connection’
(See Figure 2)
• Set ‘Master’ mode for one balancer, and the other balancer to ‘Slave’ mode.
• Connect the network cable between the two balancers.
• Connect the ‘Master’ T6B Max Balancer’s data interface cable to the charger.
• Connect the ‘Master’ Balancer to a charger.
• Connect the lithium battery pack’s balancing connectors to ‘Master’ Balancer and ‘Slave’ Balancer
in order
within
12 seconds
. (If the lithium battery pack is not connected to ‘Slave’ Balancer within
12 seconds, the ONLY Master balancer will work singly.)
• Connect the lithium battery pack’s output connectors to ‘Master’ Balancer.
• The charging and discharging of the lithium battery packs connected will be according to the
instruction of the charger/discharger.