background image

 

    I D

 

Identification number that can be assigned to each ChronoSplit, or the bib number of the racer being timed. 
(from 0001 to 9999). This allows you to track data from each ChronoSplit using separate ID numbers and to 
discern between different data sets from multiple ChronoSplit within a group of athletes. To input a new ID 
number activates SET until the leftmost digit begins to flash. Input the new number with START/STOP (+) or 
SPLIT/LAP (-). Press SET to confirm selection and proceed to the other numbers as required. This ID 
number accompanies data downloaded to PC for easy identification of different data sets. 
 

    T E A M

 

Up  to  4  different  teams  can  use  these  systems  within  the  same  immediate  area  by  setting  each  group  of 
ChronoSplit to one of four different team groups. The HL 640 – 1 transmitter must also be set to the same 
team  group  number  as  the  ChronoSplit  associated  with  those  specific  timing  points.  Activate  SET  to  enter 
the change Team number function. Use START/STOP (+) ou SPLIT/LAP (-) to select and confirm with SET.  
 

    P C

   

Allows for memory download of all stored timing session data to a PC using the appropriate RF interface and 
a USB port on the PC. Place the ChronoSplit within 2 meters / 2 yards of the USB interface kit connected to 
your PC. (see "interface" HL 640 - 2). It takes about 10 seconds to download 50 stored times. 
 

Remarks  

 
In  AUTO  SPLIT  mode,  each  radio  signal  received  from  the  transmitter  programmed  on  CHANNEL  1 
(START) shows 4 dashed ( - - - - ) on the LCD display (control of radio signal reception). 
 
If  the  ChronoSplit  does  not  receive  any  transmitted  signals  for  more  than  1  hour  it  will  automatically  enter 
TIME mode to conserve battery power. 
 
The maximum elapse time recordable in any one timing session is 15h 59'59''999

.  

 

There  is  a  rapid  access  feature  to  be  able  to  quickly  see  the  times  from  the  last  timing  session.  Activate 
MODE and press START/STOP. All times from the last recorded session are now visible. This technique can 
also momentarily black all incoming radio timing signals in AUTO SPLIT or AUTO LAP while you review the 
last timing session data on the LCD screen. This feature is particularly useful as athletes gather again at the 
start after their last timed run. ATTENTION: remember to return to AUTO SPLIT or AUTO LAP mode prior to 
the next timed run. 

 

Warning : a transmitter can’t transmit timing impulses closer than 270ms (i.e. speed measurement – distance 
between 2 photocells must be min. 10 meters at 100km/h). 
 

 

 

 

CAUTION !

 

 

NEVER

 press START/STOP, SPLIT/LAP and MODE buttons simultaneously!   

Doing so will require you to remove and replace the battery in order to reactivate 
the ChronoSplit!

 

 

Summary of Contents for Chrono Split HL 640

Page 1: ...AL Version 4 02 2007 1 1 HOW TO USE THE CHRONOSPLIT HL 640 Page 2 2 2 USING THE HL 640 1 TRANSMITTER Page 5 3 3 TECHNICAL SPECIFICATIONS Page 6 4 4 HL 640 2 USB INTERFACE DRIVER SETUP Page 7 5 5 DATA...

Page 2: ...Automatic Timing Mode with LAP functions This mode is driven by remote radio signals from the transmitters HL 640 1 attached to your timing sensors at each timing point photocells start gate etc Chann...

Page 3: ...of the USB interface kit connected to your PC see interface HL 640 2 It takes about 10 seconds to download 50 stored times Remarks In AUTO SPLIT mode each radio signal received from the transmitter p...

Page 4: ...4...

Page 5: ...dicated CHANNEL 2 For the 1 st intermediate time within a LAP times are memorized but not visible on the LCD display CHANNEL 3 For the 2 nd intermediate time within a lap inter 1 inter 2 CHANNEL 4 For...

Page 6: ...ed case Dimensions 90 x 60 x 19mm Weight 87 grams Transmitter HL 640 1 1 input for timing sensor connection via banana plugs Normally open working contact 4 programmable channel functions start interm...

Page 7: ...he new unknown device and will ask for the setup of the appropriate drivers The wizard will detect 4 devices 1 Dual RS232 FT2232C Channel A 2 Dual RS232 FT2232C Channel B 3 USB Serial Port 4 USB Seria...

Page 8: ...s select CD drivers98 Click on Continue Anyway Click Finish to close the wizard End of the setup of device 1 Device 2 FT2232C Channel B Repeat exactly the same steps as for the device 1 Device 3 USB S...

Page 9: ...all the USB interface drivers as described before Note that the two USB Serial Port can be disabled if necessary Windows Plug Play Wizard will detect a new device if you plug the USB Interface into a...

Page 10: ...lug Play Wizard will detect a new device and you will have to setup the drivers for this port as well 2 Start ChronoSplitExcel from the icon on your desktop or from the menu 3 Excel will be started an...

Page 11: ...t in seconds and thousands of a second allow you to easily calculate any type of time calculations to make custom analysis of your training data One line per session in AUTO SPLIT and MANUAL SPLIT mod...

Page 12: ...y To turn the power off press and hold the START STOP SPLIT LAP and SET buttons simultaneously for 3 seconds Switch ON OFF procedure To switch ON the ChronoSplit LCD display blank activate START STOP...

Page 13: ...gent Official representative of TAG Heuer Professional Timing 6a Rue Louis Joseph Chevrolet 2300 La Chaux de Fonds Switzerland Tel 41 32 919 8000 Fax 41 32 919 9026 E mail info tagheuer timing com Hom...

Reviews: