Drive does not run when switched to "DRIVE

ON"

6.1 Fault location

Symptom

LED 8 (Power on) does not light up.

+/- 15V (LED 5, LED 2) does not light up.

Possible causes

a) Defective fuse Si 1 on the upper PC-board
b) One phase is missing
c) No supply voltage (115V) for relays d1 and d2.

Check voltage (115V) between terminals 9 and

16

d) LED 8 or D37 defect.

a) One phase is missing
b) Check power supply, m/- 24V

a) Motor load too high.
b) Drive operates at the current limit, LED 6 lights

up.

c) Current limit is adjusted too low, drive switches

off after short operation.

d) Defective speed potentiometer.

a) Check switch-on contact (terminals 1 and 9)
b) Defective fuse Si 1 on the upper PC-board
c) LED 8 (Power on) does not light up
d) LED 9 does not light up however LED 11 lights

up, jumper or quick-stop contacts terminals 24

and 25 not closed.

e) No reference voltage (terminal 2) voltage is

variable by speed potentiometer from 0 to 10V

f) Relay d6 (malfunction) not energised. LED 3,

red, lights up. Confirmation of malfunction is

only possible if LED 4 and LED 6 do not light

up and if the field control is not activated.

g) Check three phase line input.
h) Defective fuses Si 1, Si 2 or Si 3 on lower PC-

board.

i) Check field voltage and field current.

a) I x R compensation P3 is set too high.
b) Defective tachometer or tachometer leads.
c) Stability potentiometer P8 is wrong adjusted.
d) Auxiliary winding of the d.c. motor is wrong

connected

e) Triggerinig of one Thyristor temporarely

interrupted.

Output voltage does not increase when

speed potentiometer is turned up

Drive does not run stable

Summary of Contents for TA-100/6P

Page 1: ...antriebstechnik de TA_BA TA 15 200_6P_EN PDF The German text applies in cases of doubt TA 15 6P 200 6P Instruction and Operation Manual Caution There is always a risk involved in the handling of electrical machinery Therefore mounting and maintenance should only be done by authorized personnel ...

Page 2: ...nal 4 and 9 Jog Speed ON Closing contact Drive remains switched on until contacts open 1 Technical Data r Motor Zero Speed Indicator r Current Limit control r Tachometer Signal control r Electronic circuit galvanically seperated from line when tachometer feedback is utilized Drive Type TA 15 6P TA 40 6P TA 60 6P TA 100 6P TA 200 6P Line Voltage 230VAC 400VAC 230VAC 400VAC 230VAC 400VAC 230VAC 400V...

Page 3: ...tor speed r When tachometer feedback is utilized jumpers I and VII and resistor R82 must be removed r Jumpers IX and X must be installed and jumper VIII must be removed r The adaption of the tachometer signal is achived by changing the value of resistor R91 Terminal 11 and 20 Terminals for connection of d c tachometer KL 11 Negative KL 20 Positive r Jumpers IX and X must be removed and jumper VIII...

Page 4: ...s installed or when the reference speed is changed Current limit P5 Adjustment of the requested max armature current adjust the nominal motor current Minimum Speed P6 Adjustment of min speed during operation set potentiometer fully counter clockwise Jog speed P7 Speed adjustment for jog speed Stability P8 Adjustment for the dynamical adaption to the load Maximum speed P9 Adjustment of max speed du...

Page 5: ...n center position Potentiometer P3 IxR Compensation set fully counter clockwise Potentiometer P8 Stability set in center position Potentiometer P7 Jog speed set fully counter clockwise Potentiometer P10 Delay time set fully clockwise 8 Switch on the drive LED 11 yellow Drive on and LED 9 green drive release will light up When the speed potentiometer is turned in clockwise direction the armature vo...

Page 6: ...tiometer P8 This potentiometer must be adjusted so that the drive operates without overshoot in the presset speeds 5 2 Tachometer feedback control 1 Check all connections with an Ohm meter for grounds 2 Install required jumpers for tachometer feedback control depending if a c or d c tachometer is used see page 2 terminals 19 and 20 or 11 and 20 respectively 3 Remove resistor R82 and also remove ju...

Page 7: ...ctive fuse Si 1 on the upper PC board c LED 8 Power on does not light up d LED 9 does not light up however LED 11 lights up jumper or quick stop contacts terminals 24 and 25 not closed e No reference voltage terminal 2 voltage is variable by speed potentiometer from 0 to 10V f Relay d6 malfunction not energised LED 3 red lights up Confirmation of malfunction is only possible if LED 4 and LED 6 do ...

Page 8: ...l Type TA 15 6P 200 6P a Too low adjustment of current limit b Motor is overloaded mechanical defect on machine or motor Check motor brushess c Supply voltage 15V for electronic circuit incorrect or missing Reference voltage 10V incorrect or missing Check LED 5 and LED 2 d Triggering of one Thyristor temporarely interrupted Defective tachometer or tachometer leads Defective minimum speed potentiom...

Page 9: ...R VITESSE D ACCROCHAGE Reglerfreigabe ALTERNATIF FIELD DC TACHOMETER Sollwertpotentiometer Schleichgang JOG SPEED DEBLOCAGE RUN EXCITATION Feld Anker Netz INDUIT ARMATURE ALIMENTATION EN LINE FAULT DOCKET Störmeldung G d2 E d1 S B2 E1 F1 A1 M Starting at TA 60 6P ab TA 60 6P Only by TA 40 6P availble Nur bei TA 40 6P vorhanden Strom Istwert 15V CURRENT FEEDBACK 24 L1 N 25 4 Kl 2 3 23 22 21 20 19 1...

Page 10: ...changes reserved Instruction Operating Manual TA 15 6P 200 6P 8 Mounting template TA 40 6P TA 60 6P 200 6P TA 15 6P 310 270 165 7 x 13 270 350 KL1 310 270 165 7 x 13 400 270 460 40 KL3 KL1 KL2 530 486 ø10 5 250 12 486 510 KL3 KL1 ...

Reviews: