Emerald ICE Corless Handset Quick Start Guide
Page 1-3
The user can use the above programming function keys to set up 3 dif-
ferent LED flash cadences as follows:
1.
Normal Operation
: LED Flashes [Normally]: 500ms on, 500ms
off, repeatedly. In Normal mode, the user can make/receive a call
by the handset unit through the base unit.
2.
Base In Transition Mode
: LED Flash [Slowly]: 1000ms on,
1000ms off, repeatedly. In the Transition mode, the user changes
the DIP switches status. The system will wait for 5 seconds to
ensure correct operation.
3.
Base In Register/De-Register Mode
: LED Flash [Fast]: 125ms
on, 125ms off, repeatedly. After a user changes DIP switches sta-
tus for 5 seconds, the base enters the register and/or de-register
mode. The user can register/de-register the handset to the base.
Both Registration and De-Registration must be performed within
the 20-second window in which the LED flashes in Fast mode.
NOTE:
The LED will flash fast for 20 seconds before returning to
the slow flash.
Before Programming
Prior to programming the handsets it is recommended that you perform
the
deregistration
procedures described in the next section.